{"created":"2023-05-15T14:33:15.117518+00:00","id":43116,"links":{},"metadata":{"_buckets":{"deposit":"5e5d8499-03e9-489a-a41e-536d4535812d"},"_deposit":{"created_by":1,"id":"43116","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"43116"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00043116","sets":["1"]},"author_link":["428980","428978","428979","428981"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"109","bibliographicPageStart":"105","bibliographicVolumeNumber":"255","bibliographic_titles":[{"bibliographic_title":"Journal of Radioanalytical and Nuclear Chemistry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In order to investigate the ingestion of iodine by human body and to know its content in organs, instrumental epithermal neutron activation analysis was used in conjunction with Compton suppression gamma-ray spectrometry by measuring the 128I short-lived nuclide. The interferences of 24Na and 38Cl induced from NaCl in a sample were reduced by factors of about 6 and 15 to 41 by employing the epithermal neutron activation and Compton suppression gamma-ray spectrometry, respectively. The present method can be used to determine iodine at levels higher than 11 ppb. It was applied to the determination of iodine of more than 35 ppb in various biological reference materials. ","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0236-5731","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yonezawa, Chushiro"}],"nameIdentifiers":[{"nameIdentifier":"428978","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsue, H"}],"nameIdentifiers":[{"nameIdentifier":"428979","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yukawa, Masae"}],"nameIdentifiers":[{"nameIdentifier":"428980","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"湯川 雅枝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"428981","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Non-destructive determination of trace amounts of iodine in biological samples by epithermal neutron activation and Compton suppression gamma-ray spectrometry","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Non-destructive determination of trace amounts of iodine in biological samples by epithermal neutron activation and Compton suppression gamma-ray spectrometry"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-07-04"},"publish_date":"2003-07-04","publish_status":"0","recid":"43116","relation_version_is_last":true,"title":["Non-destructive determination of trace amounts of iodine in biological samples by epithermal neutron activation and Compton suppression gamma-ray spectrometry"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:31:05.700463+00:00"}