{"created":"2023-05-15T14:33:13.622794+00:00","id":43082,"links":{},"metadata":{"_buckets":{"deposit":"e1301421-2c07-44e4-a507-fbd56a636218"},"_deposit":{"created_by":1,"id":"43082","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"43082"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00043082","sets":["1"]},"author_link":["428667","428668","428677","428670","428666","428660","428661","428675","428662","428665","428663","428664","428671","428672","428674","428669","428676","428673"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"925","bibliographicPageStart":"917","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"Advances in Space Research"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The Mobile Radiation Exposure Control System's (Liulin-4 type) main purpose is to monitor simultaneously the doses and fluxes at 4 independent places. It can also be used for personnel dosimetry. The system consists of 4 battery-operated 256-channel dosimeters-spectrometers. We describe results obtained during the calibrations of the spectrometers at the Cyclotron facilities of the University of Louvain, Belgium and of the National Institute of Radiological Sciences-STA, Chiba, Japan with protons of energies up to 70 MeV. The angular sensitivities of the devices are studied and compared with Monte-Carlo predictions. We also present the results obtained at the HIMAC accelerator with 500 MeV/u Fe ions. Records made during airplane flights are shown and compared with the predictions of the CARY-3 model.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0273-1177","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Dachev, Tsvetan"}],"nameIdentifiers":[{"nameIdentifier":"428660","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Dimitrov, Plamen"}],"nameIdentifiers":[{"nameIdentifier":"428661","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Lemaire, Jacques"}],"nameIdentifiers":[{"nameIdentifier":"428662","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Gregoire, Ghislain"}],"nameIdentifiers":[{"nameIdentifier":"428663","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Cyamukungu, Mathias"}],"nameIdentifiers":[{"nameIdentifier":"428664","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Schmitz, H"}],"nameIdentifiers":[{"nameIdentifier":"428665","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujitaka, Kazunobu"}],"nameIdentifiers":[{"nameIdentifier":"428666","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchihori, Yukio"}],"nameIdentifiers":[{"nameIdentifier":"428667","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kitamura, Hisashi"}],"nameIdentifiers":[{"nameIdentifier":"428668","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Reitz, Gunther"}],"nameIdentifiers":[{"nameIdentifier":"428669","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Beaujean, Rudolf"}],"nameIdentifiers":[{"nameIdentifier":"428670","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Petrov, Vladislav"}],"nameIdentifiers":[{"nameIdentifier":"428671","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shurshakov, Vyacheslav"}],"nameIdentifiers":[{"nameIdentifier":"428672","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Benghin, Victor"}],"nameIdentifiers":[{"nameIdentifier":"428673","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤高 和信","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"428674","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内堀 幸夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"428675","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"428676","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ブジョーン ルドルフ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"428677","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Calibration Results Obtained With Liulin-4 Type Dosimeters","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Calibration Results Obtained With Liulin-4 Type Dosimeters"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-05-08"},"publish_date":"2003-05-08","publish_status":"0","recid":"43082","relation_version_is_last":true,"title":["Calibration Results Obtained With Liulin-4 Type Dosimeters"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:31:29.320709+00:00"}