{"created":"2023-05-15T14:33:09.967169+00:00","id":42998,"links":{},"metadata":{"_buckets":{"deposit":"05947d0a-4fb3-45f8-8a01-17ee562c8178"},"_deposit":{"created_by":1,"id":"42998","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"42998"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00042998","sets":["1"]},"author_link":["427898","427901","427900","427899","427902"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageEnd":"1663","bibliographicPageStart":"1658","bibliographicVolumeNumber":"122","bibliographic_titles":[{"bibliographic_title":"電気学会論文誌. C, 電子・情報・システム部門誌"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PET動態計測では、対象臓器や放射性薬剤に応じてモデルを仮定し、各モデルパラメータを推定して機能を定量的に評価する。[18F]FDOPAを用いたドパミン代謝測定では、血漿中の代謝物も脳組織へ移行するため、モデルが複雑になりノイズの影響を受けやすい。そこで、パラメータ数を削減し、推定精度を向上させることが必要となり、いくつかの制約が臨床データの解析で用いられている。本研究では、[18F]FDOPA動態解析を対象に、これらの制約を用いたモデルに対し、シミュレーションによってノイズおよび固定値の影響を調べ、パラメータの推定精度を比較した。その結果、パラメータ数を削減するとノイズの影響は減少したが、どのパラメータを固定するかによって推定精度は異なった。また、固定値が変わるとパラメータ推定値も変化し、その場合の推定精度も各制約によって異なった。このシミュレーション結果を基に、どのパラメータを固定すれば最も精度良い推定が行えるかが分かった。今回開発した方法を基に、他の薬剤に対しても、より精度の高い解析法を検討し、実際の臨床検査に役立てることができる。","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-4221","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"生駒, 洋子"}],"nameIdentifiers":[{"nameIdentifier":"427898","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"外山, 比南子"}],"nameIdentifiers":[{"nameIdentifier":"427899","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内山, 明彦"}],"nameIdentifiers":[{"nameIdentifier":"427900","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"生駒 洋子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"427901","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"外山 比南子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"427902","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"PET動態解析におけるモデルパラメータの推定精度の検討([18F]FDOPAを用いたドパミン代謝測定におけるパラメータ数の削減)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PET動態解析におけるモデルパラメータの推定精度の検討([18F]FDOPAを用いたドパミン代謝測定におけるパラメータ数の削減)"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2002-10-23"},"publish_date":"2002-10-23","publish_status":"0","recid":"42998","relation_version_is_last":true,"title":["PET動態解析におけるモデルパラメータの推定精度の検討([18F]FDOPAを用いたドパミン代謝測定におけるパラメータ数の削減)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:32:28.371294+00:00"}