ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Study on Natural Abundance Measurement Using Flat-Laser Compton Scattering Gamma-ray Beam in UVSOR

https://repo.qst.go.jp/records/2003040
https://repo.qst.go.jp/records/2003040
3c965b1a-bcb9-4039-9ed1-52eaca368205
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2026-03-25
タイトル
タイトル Study on Natural Abundance Measurement Using Flat-Laser Compton Scattering Gamma-ray Beam in UVSOR
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference presentation
著者 Kai Nishimoto

× Kai Nishimoto

Kai Nishimoto

Search repository
Hideaki Ohgaki

× Hideaki Ohgaki

Hideaki Ohgaki

Search repository
Heishun Zen

× Heishun Zen

Heishun Zen

Search repository
Toshiyuki Shizuma

× Toshiyuki Shizuma

Toshiyuki Shizuma

Search repository
Takehito Hayakawa

× Takehito Hayakawa

Takehito Hayakawa

Search repository
Omer Mohamed

× Omer Mohamed

Omer Mohamed

Search repository
抄録
内容記述 Our research group has been studying isotope CT imaging using nuclear resonance fluorescence with energy-tunable gamma-ray beams generated by laser Compton scattering (LCS) and is currently working on simultaneous imaging of multiple isotopes and their quantitative evaluation. When an incident gamma-ray beam covers two different resonance energies of two nuclides, it is possible to obtain two CT imaging in the same measurement. For this purpose, we proposed the method that uses the helical undulator of the storage ring to broaden the energy distribution of an LCS gamma-ray beam and reduce the spatial dependence of the gamma-ray energy while keeping the small beam diameter (Flat-LCS). We also conducted experiments at the UVSOR synchrotron facility. We measured the abundance ratio of two isotopes in natural lead using the F-LCS beam and the standard LCS beam for quantitative evaluation. The PHITS simulation code has been used to optimize the experimental setup and to check the measured data during the experiment at UVSOR. We report the experimental results of the isotope abundance ratio measurement and the PHITS simulation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 Nuclear Photonics 2025
発表年月日
日付 2025-10-08
戻る
0
views
See details
Views

Versions

Ver.1 2026-04-06 06:43:48.297488
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3