ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Hybrid powdered adsorbent-spring filter system for rapid boron removal from water

https://repo.qst.go.jp/records/2003030
https://repo.qst.go.jp/records/2003030
a519ea5c-dbe7-4751-9d7e-626919244f7a
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-03-27
タイトル
タイトル Hybrid powdered adsorbent-spring filter system for rapid boron removal from water
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hoshina Hiroyuki

× Hoshina Hiroyuki

Hoshina Hiroyuki

Search repository
Omichi Masaaki

× Omichi Masaaki

Omichi Masaaki

Search repository
Amada Haruyo

× Amada Haruyo

Amada Haruyo

Search repository
Mononobe Sakiyori

× Mononobe Sakiyori

Mononobe Sakiyori

Search repository
Mononobe Nagatomo

× Mononobe Nagatomo

Mononobe Nagatomo

Search repository
Kato Motohiko

× Kato Motohiko

Kato Motohiko

Search repository
Uchimura Taizo

× Uchimura Taizo

Uchimura Taizo

Search repository
Nakano Masanori

× Nakano Masanori

Nakano Masanori

Search repository
Hosoe Tatsuya

× Hosoe Tatsuya

Hosoe Tatsuya

Search repository
Seko Noriaki

× Seko Noriaki

Seko Noriaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 The discharge concentration of boron into public water bodies is regulated to be below 10 mg L− 1 under Japan’s Water Pollution Control Law. The current drainage system needs to be supplemented with a compact, efficient, and cost-effective boron removal system to meet the needs of small and medium-sized enterprises. In this study, a powdered adsorbent with high boron affinity was synthesized via radiation-induced graft polymerization using cellulose powder as the base material. This approach enabled the development of a rapid boron removal system by integrating the adsorbent with a spring-type filter. The boron removal performance of the system was evaluated using a 10 mg L− 1 boron solution at a space velocity of 5000 h− 1. The results showed that more than 95% of boron was removed during flow-through up to a bed volume (BV) of 460. The adsorbed amount of boron reached 13 mg of boron per gram of adsorbent, demonstrating high efficiency even under rapid flow conditions.These results indicate that the developed system is highly effective for boron removal in water treatment applications.
書誌情報 Journal of Environmental Chemical Engineering

発行日 2026-03
出版者
出版者 ELSEVIER
DOI
識別子タイプ DOI
関連識別子 10.1016/j.jece.2026.122353
戻る
0
views
See details
Views

Versions

Ver.1 2026-04-06 05:24:38.773929
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3