ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

The iron and nickel spectra measured with CALET on the international space station

https://repo.qst.go.jp/records/2002893
https://repo.qst.go.jp/records/2002893
a54ff87b-34de-4f45-a12e-b312c6366c7d
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-03-05
タイトル
タイトル The iron and nickel spectra measured with CALET on the international space station
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Adriani

× Adriani

Adriani

Search repository
O

× O

O

Search repository
Akaike

× Akaike

Akaike

Search repository
Y

× Y

Y

Search repository
Uchihori Yukio

× Uchihori Yukio

Uchihori Yukio

Search repository
et al.

× et al.

et al.

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recent direct measurements of the energy spectra of the charged cosmic ray have revealed unexpected spectral features, most notably the onset of a progressive hardening at few hundreds of GeV/n not only of proton and He spectra but also observable for heavier nuclei. Thus, the study of the spectra behavior of heavy elements may shed light on understanding propagation and acceleration phenomena in our Galaxy. In particular, Fe and Ni provide favorable conditions for observations thanks to the low background contamination from spallation of higher mass elements they are affected by. The CALorimetric Electron Telescope, CALET, has been measuring high-energy cosmic rays on the International Space Station since October 2015. The instrument consists of two layers of segmented plastic scintillators, a 3 radiation length thick tungsten-scintillating fiber imaging calorimeter and a 27 radiation length thick PWO calorimeter. It identifies the charge of individual elements up to Ni and beyond and it measures the energy of cosmic-ray nuclei providing a direct measurement of their spectra. In this contribution, the iron and nickel spectra, resulted after 5 years of data acquisition, are presented in the energy range between 10 and 2000 GeV/n and between 8.8 and 240 GeV/n, respectively. The analysis procedure and the assessment of systematic errors are detailed, in addition to the ratio between the two fluxes. Both spectra show similar shape and energy dependence.
書誌情報 INTERNATIONAL JOURNAL OF MODERN PHYSICS A

巻 40, 号 08, p. 2443019, 発行日 2025-03
DOI
識別子タイプ DOI
関連識別子 10.1142/S0217751X2443019X
戻る
0
views
See details
Views

Versions

Ver.1 2026-03-05 05:28:39.036788
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3