Description of Scatter Radiation Exposure to the Eye Lenses and Direct Exposure to the Hands in Orthopedic and Spinal Procedures

https://repo.qst.go.jp/records/2002808
https://repo.qst.go.jp/records/2002808
ed8a49f5-5816-40f0-a7c7-6baf883a7316
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-02-25
タイトル
タイトル Description of Scatter Radiation Exposure to the Eye Lenses and Direct Exposure to the Hands in Orthopedic and Spinal Procedures
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yasukazu Hijikata

× Yasukazu Hijikata

Yasukazu Hijikata

Search repository
Kazuta Yamashita

× Kazuta Yamashita

Kazuta Yamashita

Search repository
Naoki Okubo

× Naoki Okubo

Naoki Okubo

Search repository
Masazumi Saito

× Masazumi Saito

Masazumi Saito

Search repository
Junji Morii

× Junji Morii

Junji Morii

Search repository
Masayuki Nakahara

× Masayuki Nakahara

Masayuki Nakahara

Search repository
Kowatari Munehiko

× Kowatari Munehiko

Kowatari Munehiko

Search repository
Matsuzaki Satoru

× Matsuzaki Satoru

Matsuzaki Satoru

Search repository
Hirai Yuta

× Hirai Yuta

Hirai Yuta

Search repository
Yosuke Yamamoto

× Yosuke Yamamoto

Yosuke Yamamoto

Search repository
Moritake Takashi

× Moritake Takashi

Moritake Takashi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Introduction: The increasing adoption of minimally-invasive spinal surgery has resulted in more frequent use of fluoroscopy, heightening concerns regarding radiation-induced cataracts and hand skin cancer in spinal surgeons. We investigated indirect and direct radiation exposure during spinal and orthopedic procedures to enhance radiation protection and explored the factors associated with high dose. Methods: We used data from 60 procedures performed in the operating and fluoroscopy rooms of a hospital in Japan between January and July 2024. Radiation doses to the eye lenses of the surgeon and scrub nurse and hands of the surgeon were measured using radiophotoluminescence glass dosimeters. Factors associated with high doses (≥0.1 mSv per procedure) were explored using the Wilcoxon rank-sum and Fisher’s exact tests. We developed a preliminary predictive model using logistic regression to identify high doses, combine key predictors, and evaluate discriminative ability.Results: In the 41 operating room procedures, the mean radiation dose to the left eye was higher than that to the right eye (0.038 mSv vs. 0.012 mSv), and the left-hand dose was also higher (0.105 mSv vs. 0.082 mSv). During the 19 fluoroscopy room procedures, the mean dose to the right eye was higher than that to the left eye (0.029 vs. 0.012 mSv), as was that to the hands (0.859 vs. 0.050 mSv). The surgeon’s hand dose reached 7.7 mSv. High doses were associated with younger age (p = 0.008), male sex (p = 0.002), and obesity (p < 0.001). A preliminary prediction model for high dose showed a c-statistic of 0.914 (95% confidence interval, 0.882-0.947). Conclusion: This study highlights the need for better radiation protection for spinal procedures, including the increased use of lead goggles and measures to prevent direct hand exposure. Findings support larger studies to develop more accurate dose estimation formulas.
書誌情報 Spine Surgery and Related Research

発行日 2025-11
DOI
識別子タイプ DOI
関連識別子 10.22603/ssrr.2025-0064
戻る
0
views
See details
Views

Versions

Ver.1 2026-02-25 23:41:27.100587
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3