ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Demonstration of Hong-Ou-Mandel Interference Using Diamond Color Center

https://repo.qst.go.jp/records/2002732
https://repo.qst.go.jp/records/2002732
93eeebda-25f0-4b3e-9687-19aacd119b1d
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2026-02-10
タイトル
タイトル Demonstration of Hong-Ou-Mandel Interference Using Diamond Color Center
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6670
資源タイプ conference poster
著者 D. Ito

× D. Ito

D. Ito

Search repository
Y. Sekiguchi

× Y. Sekiguchi

Y. Sekiguchi

Search repository
Onoda Shinobu

× Onoda Shinobu

Onoda Shinobu

Search repository
T. Makino

× T. Makino

T. Makino

Search repository
H. Kato

× H. Kato

H. Kato

Search repository
H. Kosaka

× H. Kosaka

H. Kosaka

Search repository
抄録
内容記述 Magnetometry by using NV center, a localized coherent spin consisting of a pair of nitrogen atom and atomic void, in diamond is now regarded as a promising technique due to its potential for high sensitivity and miniaturization. The primary application for NV magnetometry was realized by optically detected magnetic resonance (ODMR). There have been plenty of reports on demonstration of magnetic sensing by using ODMR1. Towards simpler and more reliable implementation of NV magnetometry, photocurrent-detected magnetic resonance2 (PDMR) is one of the key technologies to bypass the bulky confocal optics that are necessary for ODMR-based photoluminescence detection. In a PDMR scheme, meanwhile, we use photocurrent to read out the NV spin state, which necessitates laser irradiation only for photoexcitation and spin initialization. The key for high sensitivity of PDMR-based magnetometry3 is low noise to spin-dependent signal ratio. For this sake, it is essential to mitigate the unwanted spin-independent photocurrent while maximizing the PDMR signal. In this study, we employed two different laser power and time4 in the pulse sequence to improve the signal to noise ratio5. As a result, the magnetic sensitivity as high as 13 nT/Hz0.5 was achieved.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 Quantum Innovation 2025
発表年月日
日付 2025-07-30
戻る
0
views
See details
Views

Versions

Ver.1 2026-02-13 02:28:54.361669
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3