Detection of actinides in wound swabs by the measurement of spontaneously emitted characteristic x-rays

https://repo.qst.go.jp/records/2002716
https://repo.qst.go.jp/records/2002716
9ce601ac-f7cf-48d1-b511-4eb6abc7c93e
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-02-13
タイトル
タイトル Detection of actinides in wound swabs by the measurement of spontaneously emitted characteristic x-rays
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ogawa Yudai

× Ogawa Yudai

Ogawa Yudai

Search repository
Yanagisawa Ukyou

× Yanagisawa Ukyou

Yanagisawa Ukyou

Search repository
Wang Hui

× Wang Hui

Wang Hui

Search repository
Matsuyama Tsugufumi

× Matsuyama Tsugufumi

Matsuyama Tsugufumi

Search repository
Sakai Yasuhiro

× Sakai Yasuhiro

Sakai Yasuhiro

Search repository
Asai Tatsuya

× Asai Tatsuya

Asai Tatsuya

Search repository
Yoshii Hiroshi

× Yoshii Hiroshi

Yoshii Hiroshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 In the event of an accident at a nuclear fuel handling facility, the wounds of the affected workers may be contaminated with actinides such as uranium, neptunium, plutonium, and americium. The accidental absorption of actinides from wounds can lead to a significant degree of internal radiation exposure, which can be hazardous to the human body. Although the current approach for identifying actinide contamination is based on the detection of α-particles, the applicability of this approach is reduced for wound contamination due to the α-particles being easily shielded by various components of bodily fluid. Many actinide nuclides spontaneously emit characteristic x-rays during internal conversion after nuclear decay. X-rays are more penetrating than α-particles and may be easily detected even in the presence of blood. Thus, in the current study, the effects of blood on the measurement of α-particles and spontaneously emitted characteristic x-rays were evaluated using model wound swab samples containing human blood along with 241Am, which exhibits a high emission rate of characteristic x-rays. Unlike in α-particle measurements, no blood effects were observed during the measurement of spontaneously emitted characteristic x-rays. Additionally, blood-free x-ray measurements were performed using model wound swab samples containing 241Am along with 239Pu + 240Pu, which are important nuclides when considering internal exposure to actinides. In the measured spectra, signals derived from plutonium and americium were separated by peak fitting, and the detection limit of plutonium was estimated to be ∼18.8 Bq during a 300 s measurement. Notably, no previously reported methods can detect plutonium in wound swabs with such sensitivity and accuracy without pretreatment. Moreover, the developed approach allows detection using a palm-sized device, thereby reflecting a clear advantage in terms of portability and compactness.
書誌情報 Journal of Radiological Protection

巻 45, p. 031518, 発行日 2025-09
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6498/ae02a0
戻る
0
views
See details
Views

Versions

Ver.1 2026-02-13 02:12:33.984101
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3