Integration of Active Personal Dosimeters, Videos from In-Room Monitors, and Videos from the Surgeon’s Main Panel Reveal Pitfalls in Radiation Protection

https://repo.qst.go.jp/records/2002660
https://repo.qst.go.jp/records/2002660
75a497e9-b773-4139-a5ba-c0533cba9ace
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-01-29
タイトル
タイトル Integration of Active Personal Dosimeters, Videos from In-Room Monitors, and Videos from the Surgeon’s Main Panel Reveal Pitfalls in Radiation Protection
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hitomi Go

× Hitomi Go

Hitomi Go

Search repository
Moritake Takashi

× Moritake Takashi

Moritake Takashi

Search repository
Tanaka Yuko

× Tanaka Yuko

Tanaka Yuko

Search repository
Kurokawa Toru

× Kurokawa Toru

Kurokawa Toru

Search repository
Nakagami Koichi

× Nakagami Koichi

Nakagami Koichi

Search repository
Kuriyama Tomoko

× Kuriyama Tomoko

Kuriyama Tomoko

Search repository
Morota Koichi

× Morota Koichi

Morota Koichi

Search repository
Matsuzaki Satoru

× Matsuzaki Satoru

Matsuzaki Satoru

Search repository
Ishidao Toru

× Ishidao Toru

Ishidao Toru

Search repository
抄録
内容記述タイプ Abstract
内容記述 We examined whether synchronizing and analyzing three data sources, active personal dosimeter (APD) information, in-room monitoring camera footage, and the operator’s main angiography panel video, could identify opportunities to reduce occupational radiation exposure during cerebral angiography without therapeutic intervention. We analyzed the behavior of eight physicians and radiation doses measured outside the lead apron during 12 diagnostic cerebral angiography procedures performed between January and April 2024. Appropriate use of a ceiling-suspended radiation protective shield (CSRPS) was associated with approximately 70% exposure reduction. In addition, exposure during femoral arteriography (catheter advancement from femoral artery puncture to the aortic arch) accounted for approximately 50% of the total exposure, identifying both as effective intervention points. This approach identified operators’ incorrect use of radiation protection equipment and enabled clear feedback to operators on areas for improvements in radiation protection practices.
書誌情報 Applied Sciences

巻 15, 号 21, p. 11584, 発行日 2026-01
DOI
識別子タイプ DOI
関連識別子 10.3390/app152111584
戻る
0
views
See details
Views

Versions

Ver.1 2026-02-05 01:53:21.616364
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3