ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Consideration of density measurement using toroidal interferometer and polarimeter on JA DEMO

https://repo.qst.go.jp/records/2002637
https://repo.qst.go.jp/records/2002637
a421b5c3-c8aa-4ac4-a5cb-e59ecdefed3b
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2026-01-23
タイトル
タイトル Consideration of density measurement using toroidal interferometer and polarimeter on JA DEMO
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Iwasaki Kotaro

× Iwasaki Kotaro

Iwasaki Kotaro

Search repository
Sugiyama Shota

× Sugiyama Shota

Sugiyama Shota

Search repository
Ohtani Yoshiaki

× Ohtani Yoshiaki

Ohtani Yoshiaki

Search repository
Sakamoto Yoshiteru

× Sakamoto Yoshiteru

Sakamoto Yoshiteru

Search repository
抄録
内容記述タイプ Abstract
内容記述 The toroidal interferometer and polarimeter (TIP) have been investigated as density diagnostics for JA DEMO. A model for the interferometer and polarimeter phase shifts incorporating the finite electron temperature effect has been implemented into a plasma control simulation code to generate the synthetic phase shift signals. The laser wavelength is set to 10.6 μm identical to that used in ITER. The finite temperature effect is significant. The deviation between the estimated line-averaged densities obtained with and without accounting for finite temperature effects reaches approximately 7% for the interferometer and 10% for the polarimeter along lines of sight near the magnetic axis, and decreases to a few percent near the outer edge. Density feedback control has been performed, and a comparison is made between the line-averaged densities with and without correction for the temperature effect. When the temperature effect is neglected, the density is underestimated, leading to an increase in the actual density. Consequently, the fusion output increases, resulting in an error of up to 11% when using the central viewing chords. Correction of the density error caused by the finite electron temperature has been carried out using TIP alone by taking the difference between the interferometer and polarimeter signals. The results show that it can reduce the density error to below 1%.
書誌情報 Fusion Engineering and Design

巻 225, p. 115638-115638, 発行日 2026-01
出版者
出版者 ELSEVIER
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2026.115638
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-29 01:30:36.689679
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3