ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

CW operation of high-current deuteron injector for the Linear IFMIF Prototype Accelerator (LIPAc)

https://repo.qst.go.jp/records/2002576
https://repo.qst.go.jp/records/2002576
1fcda62a-bfea-4e4a-b836-5827c7600157
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2025-12-23
タイトル
タイトル CW operation of high-current deuteron injector for the Linear IFMIF Prototype Accelerator (LIPAc)
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference presentation
著者 Akagi Tomoya

× Akagi Tomoya

Akagi Tomoya

Search repository
Masuda Kai

× Masuda Kai

Masuda Kai

Search repository
Kondo Keitaro

× Kondo Keitaro

Kondo Keitaro

Search repository
Itagaki Tomonobu

× Itagaki Tomonobu

Itagaki Tomonobu

Search repository
Kitano Toshihiko

× Kitano Toshihiko

Kitano Toshihiko

Search repository
抄録
内容記述 The Linear IFMIF (International Fusion Materials Irradiation Facility) Prototype Accelerator (LIPAc) aims at validating the design of the low energy section of the 40 MeV/125 mA IFMIF deuteron accelerator up to 9 MeV in continuous-wave (CW) operation. For such a high-power deuteron accelerator, the LIPAc injector is required to provide a stable deuteron beam of 100 keV, 140 mA with low emittance (≤0.25 π mm mrad). The injector is composed of an ECR ion source based on the CEA-Saclay SILHI source and a Low Energy Beam Transport (LEBT) line. In June 2024, the commissioning of the LIPAc accelerator was completed with the acceleration and transport of a 5 MeV deuteron beam at 9% duty cycle up to the beam dump, marking the completion of Phase B+. During this phase, the injector delivered a beam that met the LIPAc requirements and achieved the acceleration of a 120-mA deuteron beam (corresponding to an extracted current from the source of 160 mA) with a RFQ transmission exceeding 90%. Afterwards, in preparation for future phases, the LIPAc team proceeded with the CW beam commissioning of the injector in stand-alone operation, achieving a long run of 24 hours of CW operation with a total extracted beam current of 150 mA. This paper presents the results of the most recent CW injector campaign and provides an update on the ongoing assessment of the ion source’s critical components and their expected lifetimes.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 International Conference on Ion Sources 2025
発表年月日
日付 2025-09-08
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-19 06:18:45.965870
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3