ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Diode-based row-column multiplexing for clinical TOF-PET detectors

https://repo.qst.go.jp/records/2002306
https://repo.qst.go.jp/records/2002306
ce18a49b-a831-4610-9a95-6f6ec851aa74
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2025-08-07
タイトル
タイトル Diode-based row-column multiplexing for clinical TOF-PET detectors
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference presentation
著者 Hangyu Kang

× Hangyu Kang

Hangyu Kang

Search repository
Yoshida Eiji

× Yoshida Eiji

Yoshida Eiji

Search repository
Akamatsu Go

× Akamatsu Go

Akamatsu Go

Search repository
Yamaya Taiga

× Yamaya Taiga

Yamaya Taiga

Search repository
抄録
内容記述 Signal multiplexing is important to reduce the complexity and cost of clinical positron emission tomography (PET) systems. In addition, good coincidence timing resolution (CTR) is also required to improve the image quality of PET by using the time-of-flight (TOF) information. Here, we report a diode-based row-column multiplexing (RC mux) circuit for clinical TOF-PET applications. A TOF detector consists of fast-LGSO crystal 8×8 array (crystal pitch=3.2 mm, thickness=20 mm) and Hamamatsu SiPM 8×8 array (S14160-3050HS, pixel pitch=3.2 mm) with one-to-one coupling (Fig. 1(a)). Custom-made RC mux circuits were developed to reduce the SiPM channels from 64 into 16 (8 x-position + 8 y-position) with diode and resistor materials, respectively (Fig. 1(b-c)). The timing information was obtained from the meantime of the x and y signals. The multiplexed analog signals were digitized by using PETsys TOFPET2 ASIC modules with an energy window of 440-560 keV (Fig. 2(a)). The effects of the RC mux circuits on the CTR were evaluated with the same crystal and SiPM arrays (Fig. 2(b)). The CTR with the diode-multiplexing was 339 ps, which was 4.3% worse and 34.5% better than the case without multiplexing (325 ps) and with resistor-based multiplexing (456 ps). In conclusion, the diode-based RC multiplexing is a cost-effective solution for the development of clinical TOF-PET systems.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 The 86th JSAP Autumn Meeting 2025
発表年月日
日付 2025-09-09
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-19 00:20:15.409932
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3