Development of a mouse brain PET scanner with sub-0.5 mm resolution

https://repo.qst.go.jp/records/2002305
https://repo.qst.go.jp/records/2002305
9fd21d04-a884-4be5-a6f8-02c8cd4e564f
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2025-08-07
タイトル
タイトル Development of a mouse brain PET scanner with sub-0.5 mm resolution
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference presentation
著者 Hangyu Kang

× Hangyu Kang

Hangyu Kang

Search repository
Tashima Hideaki

× Tashima Hideaki

Tashima Hideaki

Search repository
Wakizaka Hidekatsu

× Wakizaka Hidekatsu

Wakizaka Hidekatsu

Search repository
Higuchi Makoto

× Higuchi Makoto

Higuchi Makoto

Search repository
Yamaya Taiga

× Yamaya Taiga

Yamaya Taiga

Search repository
抄録
内容記述 For mouse brain PET imaging with high quantification accuracy, spatial resolution is the most important parameter. However, the spatial resolution of PET has been limited to over 0.5 mm for the last two decades. Here we report on a mouse brain PET design that can achieve sub-0.5 mm resolution. The developed PET scanner has a 48 mm ring diameter and 23.4 mm axial field of view. The PET scanner consists of 32 depth-of-interaction (DOI) detectors. Each DOI detector consists of a staggered 3-layer LYSO crystal array (crystal pitch=0.8 mm, total thickness= 11 mm) and silicon photomultipliers 5×5 array with a 2.4 mm pixel pitch. The physical performance of the PET scanner was evaluated according to the National Electrical Manufacturers Association NU4 protocol. In vivo mouse brain imaging was performed with 18F-FITM radiotracer. The peak axial sensitivity was 0.65% with an energy window of 440-560 keV. The spatial resolution was 0.67 mm with filtered back projection at the center. With iterative reconstruction algorithm, the 0.45 mm rod structures were clearly resolved with an average valley-to-peak ratio of 0.655±0.071. The mouse brain structures such as thalamus, hypothalamus, and cerebellum were clearly visualized. In conclusion, the developed mouse brain PET scanner achieved sub-0.5 mm resolution thereby visualizing mouse brain function in detail.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 The 86th JSAP Autumn Meeting 2025
発表年月日
日付 2025-09-09
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-18 23:55:43.847717
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3