ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

One-ring TOF-DOI brain PET prototype with crosshair light-sharing detectors

https://repo.qst.go.jp/records/2002164
https://repo.qst.go.jp/records/2002164
deac5673-6773-4a3f-b22e-274a9338f302
アイテムタイプ 会議発表用資料 / Presentation(1)
公開日 2025-06-27
タイトル
タイトル One-ring TOF-DOI brain PET prototype with crosshair light-sharing detectors
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6670
資源タイプ conference poster
著者 Akamatsu Go

× Akamatsu Go

Akamatsu Go

Search repository
Narita Kurumi

× Narita Kurumi

Narita Kurumi

Search repository
Yoshida Eiji

× Yoshida Eiji

Yoshida Eiji

Search repository
Iwao Yuma

× Iwao Yuma

Iwao Yuma

Search repository
Tashima Hideaki

× Tashima Hideaki

Tashima Hideaki

Search repository
Takahashi Miwako

× Takahashi Miwako

Takahashi Miwako

Search repository
Yamaya Taiga

× Yamaya Taiga

Yamaya Taiga

Search repository
抄録
内容記述 [Background] High spatial resolution and high sensitivity are required for brain PET to visualize small structures in the brain. Spatial resolution of PET depends on various factors such as a scintillation crystal pitch, the photon non-collinearity effect (angular deviation), the positron range, and the parallax error (depth-of-interaction (DOI) encoding error). A brain-sized compact geometry, fine scintillator pitch, and DOI measurement capability are key specifications to achieve high spatial resolution. Recently, we have developed a novel PET detector with the crosshair light-sharing (CLS) configuration that offers both time-of-flight (TOF) and DOI measurement capabilities. The scintillator pitch of the CLS detector is 1.6 mm, which is finer than other commercial brain PET systems. The purpose of this study is showing a proof-of-concept of the CLS detector by prototyping a one-ring TOF-DOI brain PET. [Methods] The fast lutetium gadolinium oxyorthosilicates (LGSO) (OXIDE, Japan) scintillators each sized at 1.45×1.45×15 mm3 were attached to a silicon photomultiplier (SiPM) (Hamamatsu Photonics, K.K., Japan) array of 3.0×3.0 mm2 pixels. The detector block consisted of a 14×14 scintillation crystal array and an 8×8 SiPM array. Two neighboring scintillators were optically glued to allow light to pass through, and other parts were covered by enhanced specular reflectors (ESRs) (3M, St. Paul, MN, USA). The combination of the optical glue and the reflectors allows scintillation light to loop within these crystals and to spread mainly among two neighboring SiPMs under a pair of crystals. DOI information was calculated from the output ratio of these two SiPMs. Thirty-six detector blocks were circularly arranged with the crystal-to-crystal diameter of 30 cm. The axial field-of-view was 2.6 cm. We used the PETsys TOFPET2 ASIC for data acquisition. Energy, timing and DOI (3-segments) calibration and normalization were performed with measuring an 18F annular distribution phantom. We evaluated the energy resolution, TOF resolution and spatial resolution, followed by imaging demonstration of the Hoffman 3D brain phantom. Only the four acrylic plates and the outer case were used so that the radioactivity was distributed within the FOV. Image reconstruction was performed with the ordered-subset expectation-maximization algorithm. To investigate the effect of the reconstruction with TOF and DOI, non-TOF and non-DOI PET data were made by post-processing. [Results] The energy resolution at 511 keV was 11.6% and the TOF resolution was 297 ps. For the spatial resolution measurement, one-millimeter rods were resolved even at the 10 cm offset position. The rod separation capability was clearly improved with DOI information. In the Hoffman brain phantom images, the gray and white matter areas were visualized with high contrast. Both TOF and DOI information effectively improved the contrast. The 0.8-mm-thick radioactivity distributions could be identified in the coronal image.[Conclusion] We developed a one-ring prototype of a TOF-DOI brain PET system with our original CLS detectors. One-millimeter rod separation capability, 0.8-mm-thick structure visibility, and 297 ps TOF resolution were demonstrated experimentally.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述 SNMMI 2025 Annual Meeting
発表年月日
日付 2025-06-24
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-16 07:02:02.543471
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3