ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparative Evaluation of Wavelength-Dependent Photodynamic Therapy Efficacy Using Representative Red and Near-Infrared Photosensitizers in a Single Tumor Model.

https://repo.qst.go.jp/records/2001907
https://repo.qst.go.jp/records/2001907
69daa5f3-064a-4c1b-8c06-54112207f647
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-10-28
タイトル
タイトル Comparative Evaluation of Wavelength-Dependent Photodynamic Therapy Efficacy Using Representative Red and Near-Infrared Photosensitizers in a Single Tumor Model.
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Winn Aung

× Winn Aung

Winn Aung

Search repository
Atsushi B Tsuji

× Atsushi B Tsuji

Atsushi B Tsuji

Search repository
Zhao-Hui Jin

× Zhao-Hui Jin

Zhao-Hui Jin

Search repository
Aya Sugyo

× Aya Sugyo

Aya Sugyo

Search repository
Chie Kajiwara

× Chie Kajiwara

Chie Kajiwara

Search repository
Tatsuya Higashi

× Tatsuya Higashi

Tatsuya Higashi

Search repository
抄録
内容記述タイプ Abstract
内容記述 IntroductionThis study aims to investigate and fairly compare the oncological therapeutic efficacy of red photodynamic therapy (Red-PDT) and near-infrared photodynamic therapy (NIR-PDT), to support the selection of suitable photosensitizers (PSs) for optimal PDT.MethodsTwo different representative PSs, trastuzumab-HiLyte Fluor™ 647 conjugate (Tra-HLF647) and trastuzumab-Indocyanine Green conjugate (Tra-ICG), activated by two laser systems at 635 nm and 808 nm, respectively, were used. To ensure a fair comparison, we used the same A4 cell line/tumor model expressing the same target, human epidermal growth factor receptor 2 (HER-2), and employed the same delivery approach. To comprehensively evaluate and compare the potential effects of Tra-HLF647-mediated Red-PDT and Tra-ICG-mediated NIR-PDT, we conducted cell viability imaging assays, intracellular reactive oxygen species (ROS) generation measurements, longitudinal monitoring of tumor volume changes, histological and immunohistochemical (IHC) analyses of tumor sections, and measurements of tumor necrotic depth.ResultsBoth PDTs exerted similar rapid cell death in cell viability imaging assays. There was no significant difference in ROS generation between cells subjected to Red-PDT and NIR-PDT. Both PDTs caused a statistically significant tumor growth delay compared to the control groups; however, no significant difference was detected between the Red-PDT and NIR-PDT groups. The H&E-stained sections of tumors that received Red-PDT and NIR-PDT showed a similar pattern of necrosis-associated features. No conspicuous tissue damage was observed in the control groups. The depth of necrosis, estimated via the coincided accumulation of a fluorescent necrosis marker (AF546-pHLIP) and utilized as an indirect index to approximate laser light penetration, was also nearly identical between tumors treated with Red-PDT and NIR-PDT.ConclusionsTarget-specific Red-PDT and NIR-PDT, using their respective PSs, demonstrated equivalent therapeutic efficacy in tumor models. These findings suggest that wavelength differences between Red-PS and NIR-PS may not critically impact treatment outcomes, offering flexibility in fluorophore selection for future PS conjugate design.
書誌情報 Technology in cancer research & treatment

巻 24, p. 1.53303E+16, 発行日 2025-01
出版者
出版者 SAGE
ISSN
収録物識別子タイプ ISSN
収録物識別子 1533-0338
PubMed番号
識別子タイプ PMID
関連識別子 41129706
DOI
識別子タイプ DOI
関連識別子 10.1177/15330338251390292
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:27:41.753420
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3