ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Characterization of beam optics considering fringe fields of quadrupole magnets in a LIPAc 5 MeV beamline

https://repo.qst.go.jp/records/2001890
https://repo.qst.go.jp/records/2001890
9dd3e891-5373-42ea-ae73-85df73102678
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-09-29
タイトル
タイトル Characterization of beam optics considering fringe fields of quadrupole magnets in a LIPAc 5 MeV beamline
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hyun Jibong

× Hyun Jibong

Hyun Jibong

Search repository
Mizuno Akihiko

× Mizuno Akihiko

Mizuno Akihiko

Search repository
Ken Takayama

× Ken Takayama

Ken Takayama

Search repository
Masuda Kai

× Masuda Kai

Masuda Kai

Search repository
Kondo Keitaro

× Kondo Keitaro

Kondo Keitaro

Search repository
C. Oliver

× C. Oliver

C. Oliver

Search repository
B. Branas

× B. Branas

B. Branas

Search repository
N. Chauvin

× N. Chauvin

N. Chauvin

Search repository
Carin Yann

× Carin Yann

Carin Yann

Search repository
H. Dzitko

× H. Dzitko

H. Dzitko

Search repository
抄録
内容記述タイプ Abstract
内容記述 This paper investigates the effect of the fringe fields of quadrupole magnets (quads) on the beam optics of a 5 MeV beamline in the Linear IFMIF Prototype Accelerator (LIPAc). IFMIF stands for the International Fusion Materials Irradiation Facility. We optimized the beam optics using a hard-edge (HE) model for all quads to minimize particle losses. However, during beam commissioning, we observed particle losses and differences in the rms beam sizes between measurements and simulations. To address these issues, we incorporated quad field maps into the beam optics simulation and calibrated the conversion coefficients of each quad from magnetic gradients g to excitation currents I (GtoI) using a 5 MeV deuteron beam. This approach enabled us to achieve a matched beam, reducing particle losses and ensuring the successful transport of a 120 mA/5 MeV deuteron beam to the beam dump. We present the difference in the transfer matrices between the HE models and the field maps, along with the calibration method of each GtoI of the quads with the deuteron beam. We also compare the simulated and measured beam sizes.
書誌情報 Journal of Physics: Conference Series

巻 3094, 号 012033, 発行日 2025-09
出版者
出版者 IOP Publishing Ltd
DOI
識別子タイプ DOI
関連識別子 10.1088/1742-6596/3094/1/012033
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:26:44.115384
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3