  1. 原著論文

Development and demonstration of an active optical axis alignment method for divertor infrared thermography system in ITER

https://repo.qst.go.jp/records/2001868
https://repo.qst.go.jp/records/2001868
fd14746a-f4c5-4c66-8634-f32f908ffc9d
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-09-02
タイトル
タイトル Development and demonstration of an active optical axis alignment method for divertor infrared thermography system in ITER
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ushiki Tomohiko

× Ushiki Tomohiko

Ushiki Tomohiko

Search repository
Imazawa Ryota

× Imazawa Ryota

Imazawa Ryota

Search repository
Sugie Tatsuo

× Sugie Tatsuo

Sugie Tatsuo

Search repository
Shimizu Kosuke

× Shimizu Kosuke

Shimizu Kosuke

Search repository
Tainaka Shunsuke

× Tainaka Shunsuke

Tainaka Shunsuke

Search repository
Kasano Naoto

× Kasano Naoto

Kasano Naoto

Search repository
Tachibana Hiroyuki

× Tachibana Hiroyuki

Tachibana Hiroyuki

Search repository
Buenavidez Butch

× Buenavidez Butch

Buenavidez Butch

Search repository
Katayanagi Yuzi

× Katayanagi Yuzi

Katayanagi Yuzi

Search repository
Nunoya Yoshihiko

× Nunoya Yoshihiko

Nunoya Yoshihiko

Search repository
抄録
内容記述タイプ Abstract
内容記述 An active alignment method to compensate for optical axis misalignment between the in-vessel and ex-vessel optics caused by thermal expansion of the vacuum vessel during plasma operation was developed in this study. By observing the return light from an alignment pattern at the vacuum window and a calibration light source positioned at the first pupil plane inside the vacuum vessel, subsequent optical axis alignment during plasma operation can be conducted using only the return light from the alignment pattern. Testing with a prototype demonstrated that the developed alignment method can align the optical axis remotely and actively with accuracies of less than 0.03° for angular decentration, less than 1 mm for parallel decentration, and less than 5 mm for optical path length displacement.
書誌情報 Review of Scientific Instruments

巻 96, p. 083505, 発行日 2025-08
DOI
識別子タイプ DOI
関連識別子 10.1063/5.0273766
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:25:43.929649