  1. 原著論文

Verification and Validation of the FENDL-3.2c library

https://repo.qst.go.jp/records/2001803
https://repo.qst.go.jp/records/2001803
e235478f-1379-4c17-a049-d2654d2a3a77
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-10-01
タイトル
タイトル Verification and Validation of the FENDL-3.2c library
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Tim Bohm

× Tim Bohm

Tim Bohm

Search repository
Daniel L Aldama

× Daniel L Aldama

Daniel L Aldama

Search repository
Georg Schnabel

× Georg Schnabel

Georg Schnabel

Search repository
Marco Fabbri

× Marco Fabbri

Marco Fabbri

Search repository
Saerom Kwon

× Saerom Kwon

Saerom Kwon

Search repository
David Laghi

× David Laghi

David Laghi

Search repository
Andrej Trkov

× Andrej Trkov

Andrej Trkov

Search repository
Alex Valentine

× Alex Valentine

Alex Valentine

Search repository
抄録
内容記述タイプ Abstract
内容記述 The Fusion Evaluated Nuclear Data Library (FENDL) provides essential nuclear data for fusion research and applications. The FENDL-3.2b release underwent comprehensive verification and validation (V&V) for neutrons, which has been reported in the associated FENDL reference paper. Since this release, a few evaluated nuclear data (ENDF) files for tungsten isotopes and thorium- 232 in the neutron sublibrary and lithium-7 in the proton sublibrary have been updated. Also, technical fixes were applied to several files in the deuteron sublibrary. The processing of ENDF files to application files in ACE format is a crucial step for applications. Several important patches have been incorporated into the NJOY2016 processing code for the generation of improved application files from the FENDL ENDF files, impacting damage cross sections, heating, the treatment of the Unresolved Resonance Range (URR) and charged-particle processing. The updated ENDF and ACE files have been released as FENDL-3.2c. This paper describes these developments and provides the results of limited V&V. Along with the development of the nuclear data library, also the data governance of the FENDL project has been improved so that all updates (including processing) are fully traceable and FENDL users can perfectly reproduce application files on their IT infrastructure.
書誌情報 FUSION SCIENCE AND TECHNOLOGY

発行日 2025-06
出版者
出版者 TAYLOR & FRANCIS INC
DOI
識別子タイプ DOI
関連識別子 10.1080/15361055.2025.25149971
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:22:42.926871
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3