Status of RIXS Beamline BL02U at NanoTerasu

https://repo.qst.go.jp/records/2001641
https://repo.qst.go.jp/records/2001641
f772be99-d4b4-4539-9ffd-c6d89ce19bba
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-07-12
タイトル
タイトル Status of RIXS Beamline BL02U at NanoTerasu
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yamamoto Kohei

× Yamamoto Kohei

Yamamoto Kohei

Search repository
Ugalino Ralph

× Ugalino Ralph

Ugalino Ralph

Search repository
Fujii Kentaro

× Fujii Kentaro

Fujii Kentaro

Search repository
Ohtsubo Yoshiyuki

× Ohtsubo Yoshiyuki

Ohtsubo Yoshiyuki

Search repository
Iwasawa Hideaki

× Iwasawa Hideaki

Iwasawa Hideaki

Search repository
Kitamura Miho

× Kitamura Miho

Kitamura Miho

Search repository
Imazono Takashi

× Imazono Takashi

Imazono Takashi

Search repository
Inami Nobuhito

× Inami Nobuhito

Inami Nobuhito

Search repository
Nakatani Takeshi

× Nakatani Takeshi

Nakatani Takeshi

Search repository
Inaba Kento

× Inaba Kento

Inaba Kento

Search repository
Agui Akane

× Agui Akane

Agui Akane

Search repository
Takeuchi Tomoyuki

× Takeuchi Tomoyuki

Takeuchi Tomoyuki

Search repository
Kimura Hiroaki

× Kimura Hiroaki

Kimura Hiroaki

Search repository
Takahashi Masamitsu

× Takahashi Masamitsu

Takahashi Masamitsu

Search repository
Horiba Koji

× Horiba Koji

Horiba Koji

Search repository
Miyawaki Jun

× Miyawaki Jun

Miyawaki Jun

Search repository
抄録
内容記述タイプ Abstract
内容記述 The monochromator disperses the incident X-rays by energy, and the sample is directly irradiated with the dispersive X-rays by placing it at the focal point. The 2D-RIXS spectrometer not only resolves the energy of the scattered X-rays but also images the spatial distribution of the incident X-rays using a 1D imaging function. By the beamline commissioning, we evaluated the focusing properties, the resolution performance of the monochromator, and the photon flux at the sample. The results showed that the focusing properties and photon flux were in excellent agreement with the design specifications. The resolving power of the beamline monochromator could not be accurately determined, since it far exceeded the limitations of measurement technique using X-ray absorption spectra of N2 gas. However, preliminary spectrometer commissioning confirmed that the combined resolving power of the beamline and spectrometer has reached the world's highest level. This directly implies that the beamline itself also possesses world-class energy resolution. These results demonstrate the exceptional performance of the BL02U beamline. The challenging final goals will be pursued through continued commissioning of both the beamline and spectrometer.
書誌情報 Journal of Physics: Conference Series

巻 3010, 号 012115, p. 1-6, 発行日 2025-06
出版者
出版者 IOP Publishing
DOI
識別子タイプ DOI
関連識別子 10.1088/1742-6596/3010/1/012115
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:59:26.688019
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3