  1. 原著論文

Diamond energy-dispersive dosimeter for measuring linear energy deposition distributions in clinical carbon beam therapy

https://repo.qst.go.jp/records/2001483
https://repo.qst.go.jp/records/2001483
f0a57936-5b56-46c4-be3b-41fcfdf79177
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-02-14
タイトル
タイトル Diamond energy-dispersive dosimeter for measuring linear energy deposition distributions in clinical carbon beam therapy
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Matsumoto Takumi

× Matsumoto Takumi

Matsumoto Takumi

Search repository
Aoki Katsumi

× Aoki Katsumi

Aoki Katsumi

Search repository
Takei Hideyuki

× Takei Hideyuki

Takei Hideyuki

Search repository
Makino Takahiro

× Makino Takahiro

Makino Takahiro

Search repository
Yonai Shunsuke

× Yonai Shunsuke

Yonai Shunsuke

Search repository
Christina Weiss

× Christina Weiss

Christina Weiss

Search repository
Erich Griesmayer

× Erich Griesmayer

Erich Griesmayer

Search repository
Ohshima Takeshi

× Ohshima Takeshi

Ohshima Takeshi

Search repository
Makoto Sakai

× Makoto Sakai

Makoto Sakai

Search repository
Akihiko Matsumura

× Akihiko Matsumura

Akihiko Matsumura

Search repository
Kada Wataru

× Kada Wataru

Kada Wataru

Search repository
抄録
内容記述タイプ Abstract
内容記述 A thin diamond membrane energy-dispersive dosimeter 50 μm thick was fabricated for estimating clinical dose distribution. In contrast to conventional semiconductors, diamond wide-bandgap semiconductors are expected to have excellent radiation tolerance and biological compatibility based on the linear relationship of stopping power ratio for clinical carbon particles. Linear energy transfer (LET) spectra were obtained along with the Bragg curve for a clinical carbon beam generated at Gunma University Heavy Ion Medical Center. The relative biological effectiveness (RBE) distributions were estimated from the LET spectra for both the mono-energy and spread-out Bragg peak irradiation configurations. The diamond detector was also used as a solid ionization chamber to obtain the radiation-induced current (RIC) distribution, which represents the physical dose distribution. The clinical dose distribution was estimated from the RIC and RBE distributions as proof of concept for the clinical carbon beam therapy field with a single-chip diamond energy-dispersive dosimeter.
書誌情報 Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms

巻 554, p. 165430, 発行日 2024-06
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2024.165430
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:54:18.899358
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3