ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Method for fabricating a mesh ripple filter for charged-particle therapy.

https://repo.qst.go.jp/records/2001444
https://repo.qst.go.jp/records/2001444
e53101db-4a21-49c3-8371-fe41c14b611b
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-01-10
タイトル
タイトル Method for fabricating a mesh ripple filter for charged-particle therapy.
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Sodai Tanaka

× Sodai Tanaka

Sodai Tanaka

Search repository
Taku Inaniwa

× Taku Inaniwa

Taku Inaniwa

Search repository
抄録
内容記述タイプ Abstract
内容記述 A simple, low-cost ripple filter consisting of multiple mesh sheets (mRiFi) was previously developed to reproducibly widen the Bragg peak of heavy-ion beams. To fabricate the mRiFi, the mRiFi parameters such as the wire material, wire diameter, wire spacing, and number of mesh sheets had to be determined. However, it was unclear how these parameters contribute to shifting and widening of the Bragg peak as well as to lateral spreading of the beam passing through the mRiFi. The purposes of this study were to clarify the contributions and to propose a recipe for fabricating a mRiFi with the desired performance values.. We established an analytical calculation method to estimate shifting and widening of the Bragg peak and lateral spreading of heavy-ion beams passing through the mRiFi for given mRiFi parameter values. We also performed Monte Carlo simulations to validate the analytical calculation method. The recipe for fabricating the mRiFi with desired performances was established based on the analytical calculation method. Using the recipe, we fabricated the mRiFi for multi-ion therapy and evaluated its performance through demonstration experiments with helium-, carbon-, oxygen-, and neon-ion beams.The difference between the results of the Monte Carlo simulation and the analytical calculation was less than 0.4 mm for the peak shift, 0.15 mm for the peak width, and less than 0.11 mm for the lateral beam size which validated the analytical calculation method. The experimentally observed shift and width of the Bragg peak were consistent with the analytical calculations.We proposed a method to determine mRiFi parameters for fabricating a mRiFi with a desired performance, i.e. adequate widening of the Bragg peak with an acceptable peak shift and lateral beam spread. The proposed method allows anyone to fabricate a simple and low-cost mRiFi satisfying desired specifications.
書誌情報 Physics in medicine and biology

巻 69, 号 14, 発行日 2024-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1361-6560
PubMed番号
識別子タイプ PMID
関連識別子 38941999
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ad5d49
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:53:03.768213
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3