  1. 原著論文

Influence of Hospital Bed Count on the Positioning of Cardiovascular Interventional Radiology (IR) Nurses: Online Questionnaire Survey of Japanese IR-Specialized Radiological Technologists.

https://repo.qst.go.jp/records/2001436
https://repo.qst.go.jp/records/2001436
ee9dbed0-34b4-4276-a228-914d6cac52d1
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-04-02
タイトル
タイトル Influence of Hospital Bed Count on the Positioning of Cardiovascular Interventional Radiology (IR) Nurses: Online Questionnaire Survey of Japanese IR-Specialized Radiological Technologists.
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Tomoko Kuriyama

× Tomoko Kuriyama

Tomoko Kuriyama

Search repository
Takashi Moritake

× Takashi Moritake

Takashi Moritake

Search repository
Go Hitomi

× Go Hitomi

Go Hitomi

Search repository
Koichi Nakagami

× Koichi Nakagami

Koichi Nakagami

Search repository
Koichi Morota

× Koichi Morota

Koichi Morota

Search repository
Satoru Matsuzaki

× Satoru Matsuzaki

Satoru Matsuzaki

Search repository
Hajime Sakamoto

× Hajime Sakamoto

Hajime Sakamoto

Search repository
Kazuma Matsumoto

× Kazuma Matsumoto

Kazuma Matsumoto

Search repository
Mamoru Kato

× Mamoru Kato

Mamoru Kato

Search repository
Hiroko Kitamura

× Hiroko Kitamura

Hiroko Kitamura

Search repository
抄録
内容記述タイプ Abstract
内容記述 Interventional radiology (IR) utilizing X-rays can lead to occupational radiation exposure, posing health risks for medical personnel in the field. We previously conducted a survey on the occupational radiation exposure of IR nurses in three designated emergency hospitals in Japan. Our findings indicated that a hospital with 214 beds showed a higher lens-equivalent dose than hospitals with 678 and 1182 beds because the distance between the X-ray irradiation field and the IR nurse's position of the hospital with 214 beds was shorter than those of 678 and 1182 beds. Based on these observations, we hypothesized that the number of hospital beds affects the distance between the X-ray irradiation field and the IR nurse's position.
書誌情報 Nursing reports (Pavia, Italy)

巻 15, 号 1, 発行日 2025-01
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 2039-4403
PubMed番号
識別子タイプ PMID
関連識別子 39852633
DOI
識別子タイプ DOI
関連識別子 10.3390/nursrep15010011
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:52:47.733514