{"created":"2025-08-15T05:51:29.442123+00:00","id":2001397,"links":{},"metadata":{"_buckets":{"deposit":"765dcbd6-d113-4ea7-95a2-63d8720dd17c"},"_deposit":{"created_by":9,"id":"2001397","owners":[9],"pid":{"revision_id":0,"type":"depid","value":"2001397"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:02001397","sets":["1"]},"author_link":[],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2024-12","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"066005","bibliographicVolumeNumber":"64","bibliographic_titles":[{"bibliographic_title":"Nuclear Fusion"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The Linear IFMIF (International Fusion Materials Irradiation Facility) Prototype Accelerator (LIPAc) is aiming at demonstrating the low-energy section of a 40 MeV/125 mA IFMIF deuteron accelerator up to 9 MeV with a full beam current in continuous-wave operation. For such a high-power beam, the LIPAc injector is required to produce a beam current of 140 mA and 100 keV D+ beams. The injector commissioning to reach high beam current has been progressing at high duty cycle operation, then stable operation for many hours at a beam\ncondition of 150 mA total extracted current. This result demonstrates that the LIPAc injector can meet the required performance for nominal 125 mA long pulse deuteron beam acceleration.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1088/1741-4326/ad37cb","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1741-4326","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Akagi Tomoya"}]},{"creatorNames":[{"creatorName":"Benoit Bolzon"}]},{"creatorNames":[{"creatorName":"Yann Carin"}]},{"creatorNames":[{"creatorName":"Nicolas Chauvin"}]},{"creatorNames":[{"creatorName":"Fabio Cismondi"}]},{"creatorNames":[{"creatorName":"Herve Dzitko"}]},{"creatorNames":[{"creatorName":"Hasegawa Kazuo"}]},{"creatorNames":[{"creatorName":"Itagaki Tomonobu"}]},{"creatorNames":[{"creatorName":"Kasugai Atsushi"}]},{"creatorNames":[{"creatorName":"Kitano Toshihiko"}]},{"creatorNames":[{"creatorName":"Kondo Keitaro"}]},{"creatorNames":[{"creatorName":"Masuda Kai"}]},{"creatorNames":[{"creatorName":"Sugimoto Masayoshi"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Achievement of high-current continuous-wave deuteron injector for linear IFMIF prototype accelerator (LIPAc)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Achievement of high-current continuous-wave deuteron injector for linear IFMIF prototype accelerator (LIPAc)","subitem_title_language":"en"}]},"item_type_id":"8","owner":"9","path":["1"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-12-10"},"publish_date":"2024-12-10","publish_status":"0","recid":"2001397","relation_version_is_last":true,"title":["Achievement of high-current continuous-wave deuteron injector for linear IFMIF prototype accelerator (LIPAc)"],"weko_creator_id":"9","weko_shared_id":-1},"updated":"2025-10-16T07:24:28.332666+00:00"}