Accurate measurement of the localized degree of grafting using thermogravimetric analysis

https://repo.qst.go.jp/records/2001384
https://repo.qst.go.jp/records/2001384
b894e686-573c-44d9-8e30-b610d83eab96
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-12-11
タイトル
タイトル Accurate measurement of the localized degree of grafting using thermogravimetric analysis
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Omichi Masaaki

× Omichi Masaaki

Omichi Masaaki

Search repository
Hoshina Hiroyuki

× Hoshina Hiroyuki

Hoshina Hiroyuki

Search repository
Morishima Hidenobu

× Morishima Hidenobu

Morishima Hidenobu

Search repository
Ohshima Kunihiro

× Ohshima Kunihiro

Ohshima Kunihiro

Search repository
Seko Noriaki

× Seko Noriaki

Seko Noriaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 A method for accurately measuring the degree of grafting (DG) in a small area of several tens of square millimeters to several tens of square centimeters is proposed. This method employs thermogravimetric analysis to take advantage of the similarity in pyrolysis behavior of grafted materials with similar DGs. A pre-irradiation method is used for graft polymerization with an acrylic acid monomer to a cotton fibers substrate, and the proposed method is used to quantify the DG of the grafted material. Cryo-milling is used to homogenize the grafted material, and reference samples with known DGs (DG: 1.9 %?107.0 %) are prepared. Subsequently, localized DG is determined by measuring the pyrolysis behavior and comparing it to that of the reference samples. In experiments, the proposed method accurately predicts the DGs of test samples with a difference of
<1.0 % from gravimetric measurements, especially at low DGs of 0 %?40.0 %. The proposed method can also detect the DG distribution of a cotton fiber substrate with a thickness of <1 mm. The proposed method is expected to be useful for detecting heterogeneous graft reactions and improving quality control of grafted materials in industrial applications.
書誌情報 Polymer Degradation and Stability

巻 231, p. 111087, 発行日 2024-11
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 1873-2321
DOI
識別子タイプ DOI
関連識別子 10.1016/j.polymdegradstab.2024.111087
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:51:07.388881
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3