A performance comparison study between two HPGe lung counters with different detector configurations

https://repo.qst.go.jp/records/2001317
https://repo.qst.go.jp/records/2001317
d329aa77-29b7-4433-a5eb-8f7fa13d9b8c
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-02-26
タイトル
タイトル A performance comparison study between two HPGe lung counters with different detector configurations
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Naito Masayuki

× Naito Masayuki

Naito Masayuki

Search repository
Tamakuma Yuki

× Tamakuma Yuki

Tamakuma Yuki

Search repository
Mihei Yuma

× Mihei Yuma

Mihei Yuma

Search repository
Yajima Kazuaki

× Yajima Kazuaki

Yajima Kazuaki

Search repository
Tani Kotaro

× Tani Kotaro

Tani Kotaro

Search repository
Kim Eunjoo

× Kim Eunjoo

Kim Eunjoo

Search repository
Kowatari Munehiko

× Kowatari Munehiko

Kowatari Munehiko

Search repository
Kurihara Osamu

× Kurihara Osamu

Kurihara Osamu

Search repository
抄録
内容記述タイプ Abstract
内容記述 This study compares the performance of old and new lung counters in the National Institutes for Quantum Sciences and Technology of Japan. The total sensitive area of the detector crystals for the new lung counter is ?15% smaller than that for the old lung counter. Minimum detectable activities (MDAs) for 241Am and 239Pu were evaluated through experiments using a Lawrence Livermore National Laboratory torso phantom. Despite differences in detector configuration, the MDAs were found to be comparable between the two lung counters. For a chest wall thickness of 2.1 cm and a counting time of 30 min, the MDAs of 241Am and 239Pu were 5.7 and 2300 Bq for the old lung counter, and 5.5 and 2600 Bq for the new lung counter, respectively. Experimental results for the relative sensitivities between left-side and right-side detectors suggested that the new lung counter offered better measurement geometry.
書誌情報 Radiation Protection Dosimetry

発行日 2024-09
出版者
出版者 Oxford University Press
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:48:55.675604
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3