  1. 原著論文

DOCK?PET: database of CNS kinetic parameters in the healthy human brain for existing PET tracers

https://repo.qst.go.jp/records/2001214
https://repo.qst.go.jp/records/2001214
dcea650b-d90e-4735-9e12-14e0b3cf60d1
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-05-31
タイトル
タイトル DOCK?PET: database of CNS kinetic parameters in the healthy human brain for existing PET tracers
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Itsuki Miyajima

× Itsuki Miyajima

Itsuki Miyajima

Search repository
Ayano Yoshikawa

× Ayano Yoshikawa

Ayano Yoshikawa

Search repository
Kyosei Sahashi

× Kyosei Sahashi

Kyosei Sahashi

Search repository
Seki Chie

× Seki Chie

Seki Chie

Search repository
Nagai Yuji

× Nagai Yuji

Nagai Yuji

Search repository
Watabe Hiroshi

× Watabe Hiroshi

Watabe Hiroshi

Search repository
Shidahara Miho

× Shidahara Miho

Shidahara Miho

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose Information about developed positron emission tomography (PET) tracers and obtained clinical PET images is publicly available in a database. However, findings regarding the kinetic parameters of PET tracers are yet to be summarized. Therefore, in this study, we created an open-access database of central nervous system (CNS) kinetic parameters in
the healthy human brain for existing PET tracers (DOCK?PET).
Methods Our database includes information on the kinetic parameters and compounds of existing CNS?PET tracers. The kinetic parameter dataset comprises the analysis methods, VT, BPND, K parameters, relevant literature, and study details. The list of PET tracers and kinetic parameter information was compiled through keyword-based searches of PubMed and the Molecular Imaging and Contrast Agent Database (MICAD). The kinetic parameters obtained, including VT, BPND, and K parameters, were reorganized based on the defined brain anatomical regions. All data were rigorously double-checked
before being summarized in Microsoft Excel and JavaScript Object Notation (JSON) formats.
Results Of the 247 PET tracers identified through searches using the PubMed and MICAD websites, the kinetic parameters of 120 PET tracers were available. Among the 120 PET tracers, compound structures with chemical and physical properties were obtained from the PubChem website or the ChemDraw software. Furthermore, the affinity information of the 104 PET tracers was gathered from PubChem or extensive literature surveys of the 120 PET tracers.
Conclusions We developed a comprehensive open-access database, DOCK?PET, that includes both kinetic parameters of healthy humans and compound information for existing CNS?PET tracers.
書誌情報 Annals of Nuclear Medicine

発行日 2024-05
PubMed番号
識別子タイプ PMID
関連識別子 38814564
DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.1007/s12149-024-01947-z
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 04:47:06.063281
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3