  1. 原著論文

Development of advanced ternary beryllium intermetallic compounds

https://repo.qst.go.jp/records/2001045
https://repo.qst.go.jp/records/2001045
7a57e441-0d28-4523-b95f-42e734662031
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-02-13
タイトル
タイトル Development of advanced ternary beryllium intermetallic compounds
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Taehyun Hwang

× Taehyun Hwang

Taehyun Hwang

Search repository
Jaehwan Kim

× Jaehwan Kim

Jaehwan Kim

Search repository
Sugimoto Yutaka

× Sugimoto Yutaka

Sugimoto Yutaka

Search repository
Akatsu Yoshiaki

× Akatsu Yoshiaki

Akatsu Yoshiaki

Search repository
Nakano Suguru

× Nakano Suguru

Nakano Suguru

Search repository
Nakamichi Masaru

× Nakamichi Masaru

Nakamichi Masaru

Search repository
抄録
内容記述タイプ Abstract
内容記述 A ternary beryllide was prepared by mixing Be12V with Be12Ti and using plasma sintering. After preparation at a pressure of 54 MPa for 20 min at 1200 ?C, the changes in mechanical and thermal properties due to the addition of 1 wt.% Be12V and 10 wt.% Be12V were investigated. The Vickers hardness of both Be12Ti+1 wt.%Be12V and Be12Ti+10 wt.%Be12V were lower than Be12Ti. In addition, the fracture toughness was calculated using the IF method, and the calculation formula was calculated using various equations. According to the Anstis equation, it was 3.23 ± 0.13 MPa?m0.5 for Be12Ti, and it increased to 4.47 ± 0.13 MPa?m0.5 for Be12Ti+1 wt.%Be12V. As Be12V was added, it increased compared to Be12Ti. In the case of thermal properties, the thermal diffusivity of Be12Ti and Be12Ti+1 wt.%Be12V showed almost the same value, while that of Be12Ti+10 wt.%Be12V was lower than others. In the case of specific heat, moreover, it tended to decrease as the temperature increased in comparison to Be12Ti. This trend was particularly evident when 10 wt.% Be12V was added. Thus, the results of the thermal conductivity calculation indicated a decrease in tendency as the amount of addition increased in comparison to Be12Ti. Therefore, the addition of 1 wt.% Be12V seems to be more effective than the addition of 10 wt.% Be12V.
書誌情報 fusion engineering and design

巻 200, 発行日 2024-02
出版者
出版者 Elsevier B.V.
DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.fusengdes.2024.114221
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 04:41:37.948345
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3