  1. 原著論文

Helium swelling behavior for neutron multipliers after irradiation with He ions at high temperatures

https://repo.qst.go.jp/records/2001033
https://repo.qst.go.jp/records/2001033
da7acd47-ab51-408a-925c-cc6433887196
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-02-29
タイトル
タイトル Helium swelling behavior for neutron multipliers after irradiation with He ions at high temperatures
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Sugimoto Yutaka

× Sugimoto Yutaka

Sugimoto Yutaka

Search repository
杉本 有隆

× 杉本 有隆

杉本 有隆

Search repository
Mitsutaka Miyamoto

× Mitsutaka Miyamoto

Mitsutaka Miyamoto

Search repository
Jaehwan Kim

× Jaehwan Kim

Jaehwan Kim

Search repository
Taehyun Hwang

× Taehyun Hwang

Taehyun Hwang

Search repository
Nakamichi Masaru

× Nakamichi Masaru

Nakamichi Masaru

Search repository
抄録
内容記述タイプ Abstract
内容記述 Beryllides as beryllium intermetallic compounds are the advanced multiplier materials as candidate materials for fusion demonstration power plant (DEMO) due to
having good properties such as low swelling rate and stable chemical properties.
Under DEMO operation environment, the generated He amounts in beryllium are estimated around 20,000 appm He. This study was evaluated the effect of He
fluence and irradiation temperature on the bubble behaviors in Be12Ti and beryllium. The irradiation of He ion was carried out using an In-situ transmission electron
microscope equipped with an ion gun by implantation up to 25,000 appm He. For comparison, beryllium was carried out in similar experiments.
Bubbles were observed in Be12Ti at 873 K after the implantation of 15,000 appm He, while in Be at the same temperature, their appearance occurred postimplantation of 4,500 appm He. In addition, growth of bubbles in beryllium was observed with increase of He ion fluence. Sizes and densities of bubbles in
Be12Ti and beryllium were evaluated irradiated in 25,000 appm He at 673 and 873 K.
In the case of Be12Ti, fine bubbles were observed in a high density state, and it was found that the swelling rate was a few percent. By contrast, bubbles in beryllium had a diameter in the range from tens to several tens nanometers, and growth of these bubbles were observed. The swelling rate of beryllium was approximately 18%.
書誌情報 Nuclear Materials and Energy

号 38, 発行日 2024-01
出版者
出版者 Elsevier
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 04:41:15.012325
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3