WEKO3
アイテム
Effects of resonance phenomenon and transient response on voltage between conductor in JT-60SA PF coils
https://repo.qst.go.jp/records/2001018
https://repo.qst.go.jp/records/2001018844f7267-b69c-44b6-ba06-b9c563ffbc17
| アイテムタイプ | 学術雑誌論文 / Journal Article(1) | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2024-02-12 | |||||||||||||||||||||||
| タイトル | ||||||||||||||||||||||||
| タイトル | Effects of resonance phenomenon and transient response on voltage between conductor in JT-60SA PF coils | |||||||||||||||||||||||
| 言語 | en | |||||||||||||||||||||||
| 言語 | ||||||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||
| 資源タイプ | journal article | |||||||||||||||||||||||
| 著者 |
Sonoda Shogo
× Sonoda Shogo
× Nakamura Kazuya
× Yuinawa Kotomi
× Kobayashi Tomoka
× Yoshida Suzuka
× Murakami Haruyuki
× Hamada Kazuya
× Hatakeyama Shoichi
× Shimada Katsuhiro
|
|||||||||||||||||||||||
| 抄録 | ||||||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||||||
| 内容記述 | The JT-60SA Poloidal Field (PF) coils system comprises four Central Solenoid (CS) modules and six Equilibrium Field (EF) coils, and the cryostat, vacuum vessel (VV), and stabilizing plate (SP) are installed around the PF coil. Evaluating the voltage between conductors in the PF coils is one of the most critical factors in the energized coil operation and the insulation design. The power supply voltage of the PF coils has some frequency components caused by the voltage control system. The resonance phenomena caused by the voltage fluctuations of the power supply induce a non-uniform voltage distribution in the coil. The locally concentrated voltage may exceed the withstand voltage of the insulation, affecting the operation of the JT-60SA. In this study, a circuital model was assembled including four CS modules and six EF coils, to estimate the resonance frequency effect into the coil voltage distribution. In addition, the effects of the cryostat, VV, and SP on the voltage between conductors in the PF coils were evaluated. | |||||||||||||||||||||||
| 書誌情報 |
IEEE Transactions on Applied Superconductivity 巻 34, 号 5, 発行日 2024-08 |
|||||||||||||||||||||||
| 出版者 | ||||||||||||||||||||||||
| 出版者 | IEEE | |||||||||||||||||||||||
| ISSN | ||||||||||||||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||||||||||||||
| 収録物識別子 | 1558-2515 | |||||||||||||||||||||||
| DOI | ||||||||||||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||||||||||
| 関連識別子 | 10.1109/TASC.2024.3358269 | |||||||||||||||||||||||