Effects of resonance phenomenon and transient response on voltage between conductor in JT-60SA PF coils

https://repo.qst.go.jp/records/2001018
https://repo.qst.go.jp/records/2001018
844f7267-b69c-44b6-ba06-b9c563ffbc17
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-02-12
タイトル
タイトル Effects of resonance phenomenon and transient response on voltage between conductor in JT-60SA PF coils
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Sonoda Shogo

× Sonoda Shogo

Sonoda Shogo

Search repository
Nakamura Kazuya

× Nakamura Kazuya

Nakamura Kazuya

Search repository
Yuinawa Kotomi

× Yuinawa Kotomi

Yuinawa Kotomi

Search repository
Kobayashi Tomoka

× Kobayashi Tomoka

Kobayashi Tomoka

Search repository
Yoshida Suzuka

× Yoshida Suzuka

Yoshida Suzuka

Search repository
Murakami Haruyuki

× Murakami Haruyuki

Murakami Haruyuki

Search repository
Hamada Kazuya

× Hamada Kazuya

Hamada Kazuya

Search repository
Hatakeyama Shoichi

× Hatakeyama Shoichi

Hatakeyama Shoichi

Search repository
Shimada Katsuhiro

× Shimada Katsuhiro

Shimada Katsuhiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 The JT-60SA Poloidal Field (PF) coils system comprises four Central Solenoid (CS) modules and six Equilibrium Field (EF) coils, and the cryostat, vacuum vessel (VV), and stabilizing plate (SP) are installed around the PF coil. Evaluating the voltage between conductors in the PF coils is one of the most critical factors in the energized coil operation and the insulation design. The power supply voltage of the PF coils has some frequency components caused by the voltage control system. The resonance phenomena caused by the voltage fluctuations of the power supply induce a non-uniform voltage distribution in the coil. The locally concentrated voltage may exceed the withstand voltage of the insulation, affecting the operation of the JT-60SA. In this study, a circuital model was assembled including four CS modules and six EF coils, to estimate the resonance frequency effect into the coil voltage distribution. In addition, the effects of the cryostat, VV, and SP on the voltage between conductors in the PF coils were evaluated.
書誌情報 IEEE Transactions on Applied Superconductivity

巻 34, 号 5, 発行日 2024-08
出版者
出版者 IEEE
ISSN
収録物識別子タイプ ISSN
収録物識別子 1558-2515
DOI
識別子タイプ DOI
関連識別子 10.1109/TASC.2024.3358269
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 04:40:47.639788