ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Measurement of the Sub-nanometer Vibration Amplitudes Using 57Fe Synchrotron Mossbauer Source

https://repo.qst.go.jp/records/2000979
https://repo.qst.go.jp/records/2000979
ae740507-923c-467f-9b5b-14e9d369cdfd
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-02-06
タイトル
タイトル Measurement of the Sub-nanometer Vibration Amplitudes Using 57Fe Synchrotron Mossbauer Source
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hiroyuki Yamashita

× Hiroyuki Yamashita

Hiroyuki Yamashita

Search repository
Shinji Kitao

× Shinji Kitao

Shinji Kitao

Search repository
Yasuhiro Kobayashi

× Yasuhiro Kobayashi

Yasuhiro Kobayashi

Search repository
Hidetoshi Ota

× Hidetoshi Ota

Hidetoshi Ota

Search repository
Ryo Masuda

× Ryo Masuda

Ryo Masuda

Search repository
Kosuke Fujiwara

× Kosuke Fujiwara

Kosuke Fujiwara

Search repository
Takaya Mitsui

× Takaya Mitsui

Takaya Mitsui

Search repository
Makoto Seto

× Makoto Seto

Makoto Seto

Search repository
抄録
内容記述タイプ Abstract
内容記述 The sub-nanometer amplitudes of the samples vibrated with high frequencies were measured by 57Fe Mossbauer spectroscopy using a nuclear Bragg monochromator and focusing optics. The Mossbauer spectra of the vibrated single-line absorber showed comb-like absorption peaks due to the frequency modulation of the gamma rays, and the amplitudes of the absorbers were determined by the sideband intensities. We used the stainless-steel foil glued on the quartz crystal or the polyvinylidene fluoride (PVDF) film as samples. The mean value and the variance of the amplitude in sub-nanometer order were obtained for the irradiated area of 100 μm diameter in the sample. We could obtain the sub-nanometer amplitude with almost zero variance, using the 57Fe synchrotron Mossbauer source and focusing optics for the PVDF film. Therefore, this method makes it possible to produce the high-quality coherent frequency-modulated gamma rays. This method is useful for the control of gamma rays. This work will advance X-ray quantum optics and quantum technology applications using a single gamma photon.
書誌情報 Hyperfine Interactions

巻 245, p. 15, 発行日 2024-02
DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.1007/s10751-024-01854-9
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 04:39:31.605340
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3