ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Experimental study and suggestions on the relative biological effectiveness of low-dose tritium

https://repo.qst.go.jp/records/2000972
https://repo.qst.go.jp/records/2000972
b2fa4f85-9f6c-4d2a-bbaa-6021d5fd8b63
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-01-04
タイトル
タイトル Experimental study and suggestions on the relative biological effectiveness of low-dose tritium
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Fengmei Cui

× Fengmei Cui

Fengmei Cui

Search repository
Wang Bing

× Wang Bing

Wang Bing

Search repository
Hua Zhao

× Hua Zhao

Hua Zhao

Search repository
Xiangyan Zhou

× Xiangyan Zhou

Xiangyan Zhou

Search repository
抄録
内容記述タイプ Abstract
内容記述 Studies on the relative biological effectiveness (RBE) of tritium as nuclear fusion fuel under low-dose irradiation from the perspective of radiation protection were summarized. Two tritium irradiation methods, namely, exponentially decreasing dose rate and constant dose rate, were selected to observe and analyze the following biological indicators: dominant lethal mutation rate in oocytes and spermatocytes, dominant skeletal mutation rate, survival rate of primary oocytes and spermatogonia, and micronucleus cell rate in peripheral blood lymphocytes and polychromatic erythrocytes of fetal liver. The RBE under these two tritium irradiation methods was calculated, and the factors influencing the RBE were analyzed. Results showed that at cumulative doses of 0.2, 0.3, 0.4, 0.5, and 0.6 Gy/10 d, the RBE under the tritium irradiation methods of exponentially decreasing dose rate and constant dose rate was 2.9?4.2. For radiation protection, the RBE of low-linear energy transfer (LET) radiation on the biome must be set to 3.0?3.5. In case of exposure to tritium β particles or other low-LET radiation or values close to the derived reference level, a high RBE may be required for an accurate estimation of the radiation risk.
書誌情報 International Journal of Radiation Medicine and Nuclear Medicine.

巻 47, 号 10, p. 608-614, 発行日 2023-12
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 04:39:20.088917
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3