ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Magnetic Resonance Water Tracer Imaging Using 17O-Labeled Water.

https://repo.qst.go.jp/records/2000861
https://repo.qst.go.jp/records/2000861
177b23a4-a983-4865-84b1-2d17353dba8f
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-05-07
タイトル
タイトル Magnetic Resonance Water Tracer Imaging Using 17O-Labeled Water.
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hiroyuki Kameda

× Hiroyuki Kameda

Hiroyuki Kameda

Search repository
Naoya Kinota

× Naoya Kinota

Naoya Kinota

Search repository
Daisuke Kato

× Daisuke Kato

Daisuke Kato

Search repository
Takaaki Fujii

× Takaaki Fujii

Takaaki Fujii

Search repository
Taisuke Harada

× Taisuke Harada

Taisuke Harada

Search repository
Yuji Komaki

× Yuji Komaki

Yuji Komaki

Search repository
Hiroyuki Sugimori

× Hiroyuki Sugimori

Hiroyuki Sugimori

Search repository
Tomohiro Onodera

× Tomohiro Onodera

Tomohiro Onodera

Search repository
Moyoko Tomiyasu

× Moyoko Tomiyasu

Moyoko Tomiyasu

Search repository
Takayuki Obata

× Takayuki Obata

Takayuki Obata

Search repository
Kohsuke Kudo

× Kohsuke Kudo

Kohsuke Kudo

Search repository
抄録
内容記述タイプ Abstract
内容記述 Magnetic resonance imaging (MRI) is a crucial imaging technique for visualizing water in living organisms. Besides proton MRI, which is widely available and enables direct visualization of intrinsic water distribution and dynamics in various environments, MR-WTI (MR water tracer imaging) using 17O-labeled water has been developed, benefiting from the many advancements in MRI software and hardware that have substantially improved the signal-to-noise ratio and made possible faster imaging. This cutting-edge technique allows the generation of novel and valuable images for clinical use. This review elucidates the studies related to MRI water tracer techniques centered around 17O-labeled water, explaining the fundamental principles of imaging and providing clinical application examples. Anticipating continued progress in studies involving isotope-labeled water, this review is expected to contribute to elucidating the pathophysiology of various diseases related to water dynamics abnormalities and establishing novel imaging diagnostic methods for associated diseases.
書誌情報 Investigative radiology

巻 59, 号 1, p. 92-103, 発行日 2023-09
出版者
出版者 Wolters Kluwer Health, Inc
ISSN
収録物識別子タイプ ISSN
収録物識別子 1536-0210
PubMed番号
識別子タイプ PMID
関連識別子 37707860
DOI
識別子タイプ DOI
関連識別子 10.1097/RLI.0000000000001021
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 03:03:29.324123
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3