Impact of varying the number of irradiation fields on dose distribution: a four-dimensional scanned carbon-ion lung radiotherapy

https://repo.qst.go.jp/records/2000720
https://repo.qst.go.jp/records/2000720
5570d5a6-ecb8-4fbb-99fa-1bee518771d4
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-12-02
タイトル
タイトル Impact of varying the number of irradiation fields on dose distribution: a four-dimensional scanned carbon-ion lung radiotherapy
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Pengbo He

× Pengbo He

Pengbo He

Search repository
Mori Shinichiro

× Mori Shinichiro

Mori Shinichiro

Search repository
Ono Takashi

× Ono Takashi

Ono Takashi

Search repository
Nomoto Akihiro

× Nomoto Akihiro

Nomoto Akihiro

Search repository
Ishikawa Hitoshi

× Ishikawa Hitoshi

Ishikawa Hitoshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 To shorten the treatment procedure and increase the treatment efficiency, we performed planning studies to evaluate the 4D dose (4DD) distributions of different number of irradiation fields with the fixed treatment ports of scanning carbon-ion beam delivery. We enrolled 10 lung cancer patients treated with respiratory-gated scanning carbon-ion therapy. 4-field, 3-field, and 2-field plans were generated with fixed treatment ports by rotating the beam angle with a 20~40-degree difference. For each field, the range-adapted internal target volume (raITV) was calculated. The prescription dose of 50 Gy (RBE)-weighted dose with 1 fraction was optimized on the reference phase (T50). The 4DD distributions were calculated for each patient, and dose metrics of CTV dose coverage and OARs sparing were evaluated. p<0.05 was considered to be statistically significant by Wilcoxon signed-rank test. The sufficient CTV-D95 >97.8 % could be achieved for all the three types of treatment plan. The Dmax of skin was increased (= 19.1 ± 5.7 Gy (RBE)) for the 2-field plans as compared to 4-field plans (= 14.2 ± 6.6 Gy (RBE), p = 0.006), which is still acceptable for clinical use (< 35 Gy (RBE)). And there were no differences (p>0.076) of V20 of lung (= 15.5 ± 6.6 %, 16.2 ± 7.0 %, 15.6 ± 6.3 %) and Dmax of spinal cord (= 3.0±2.9, 3.4±3.9, 3.3±4.3 Gy (RBE)) among the three types of plans. Lung treatment plans under the fixed orthogonal beam ports with zero-degree couch pitch angle is feasible for clinical use to further increase the treatment efficiency and throughput.
書誌情報 Radiation physics and chemistry

巻 212, p. 111183, 発行日 2023-07
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 1879-0895
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radphyschem.2023.111183
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:58:55.777437
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3