Prompt X-ray imaging during irradiation with spread-out Bragg peak (SOBP) beams of carbon ions

https://repo.qst.go.jp/records/2000625
https://repo.qst.go.jp/records/2000625
b7c8d517-b833-4c13-8c45-6a4e78e05bbe
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-08-30
タイトル
タイトル Prompt X-ray imaging during irradiation with spread-out Bragg peak (SOBP) beams of carbon ions
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yamamoto Seiichi (Waseda Univ.)

× Yamamoto Seiichi (Waseda Univ.)

Yamamoto Seiichi (Waseda Univ.)

Search repository
Yabe Takuya

× Yabe Takuya

Yabe Takuya

Search repository
Akagi Takashi (Hyogo Ion Beam Medical Center)

× Akagi Takashi (Hyogo Ion Beam Medical Center)

Akagi Takashi (Hyogo Ion Beam Medical Center)

Search repository
Yamaguchi Mitsutaka

× Yamaguchi Mitsutaka

Yamaguchi Mitsutaka

Search repository
Kawachi Naoki

× Kawachi Naoki

Kawachi Naoki

Search repository
Kamada Kei (Tohoku Univ.)

× Kamada Kei (Tohoku Univ.)

Kamada Kei (Tohoku Univ.)

Search repository
Yoshikawa Akira (Tohoku Univ.)

× Yoshikawa Akira (Tohoku Univ.)

Yoshikawa Akira (Tohoku Univ.)

Search repository
Kataoka Jun (Waseda Univ.)

× Kataoka Jun (Waseda Univ.)

Kataoka Jun (Waseda Univ.)

Search repository
抄録
内容記述タイプ Abstract
内容記述 Prompt secondary electron bremsstrahlung X-ray (prompt X-ray) imaging using a low-energy X-ray camera is a promising method for observing a beam shape from outside the subject. However, such imaging has so far been conducted only for pencil beams without a multi-leaf collimator (MLC). The use of spread-out Bragg peak (SOBP) with an MLC may increase the scattered prompt gamma photons and decrease the contrast of the images of prompt X-rays. Consequently, we performed prompt X-ray imaging of SOBP beams formed with an MLC. This imaging was carried out in list mode during irradiation of SOBP beams to a water phantom. An X-ray camera with a 1.5-mm diameter as well as 4-mm-diameter pinhole collimators was used for the imaging. List mode data were sorted to obtain the SOBP beam images as well as energy spectra and time count rate curves. Due to the high background counts from the scattered prompt gamma photons penetrating the tungsten shield of the X-ray camera, the SOBP beam shapes were difficult to observe with a 1.5-mm-diameter pinhole collimator. With the 4-mm-diameter pinhole collimators, images of SOBP beam shapes at clinical dose levels could be obtained with the X-ray camera. The use of a 4-mm-diameter pinhole collimator attached to the X-ray camera is effective for prompt X-ray imaging with high sensitivity and low background counts. This approach makes it possible to image SOBP beams with an MLC when the counts are low and the background levels are high.
書誌情報 Physica Medica

巻 109, p. 102592, 発行日 2023-04
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 1120-1797
DOI
識別子タイプ DOI
関連識別子 10.1016/j.ejmp.2023.102592
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:25:48.522489
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3