  1. 原著論文

Effects of He ion and electron beam irradiation on a CdTe solar cell dosimeter in a substrate configuration

https://repo.qst.go.jp/records/2000547
https://repo.qst.go.jp/records/2000547
4f99049f-3c7c-457e-b42f-547c24a5c3ca
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-07-18
タイトル
タイトル Effects of He ion and electron beam irradiation on a CdTe solar cell dosimeter in a substrate configuration
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Tamotsu Okamoto

× Tamotsu Okamoto

Tamotsu Okamoto

Search repository
Fumiya Furumaki

× Fumiya Furumaki

Fumiya Furumaki

Search repository
Eiku Sato

× Eiku Sato

Eiku Sato

Search repository
Ippei Isogai

× Ippei Isogai

Ippei Isogai

Search repository
Yuji Kurimoto

× Yuji Kurimoto

Yuji Kurimoto

Search repository
Yasuki Okuno

× Yasuki Okuno

Yasuki Okuno

Search repository
Mitsuru Imaizumi

× Mitsuru Imaizumi

Mitsuru Imaizumi

Search repository
Masafumi Akiyoshi

× Masafumi Akiyoshi

Masafumi Akiyoshi

Search repository
Ohshima Takeshi

× Ohshima Takeshi

Ohshima Takeshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The effects of He ion and electron beam irradiation on substrate-type CdTe solar cells that are suitable for the detection of alpha and beta radiation are investigated. He ion irradiation revealed that the induced current proportionally increased with the increase of He ion current and that it is possible to detect alpha radiation using a substrate-type CdTe solar cell dosimeter. Next, the electron irradiation effects were investigated. The induced current proportional to the electron flux was also observed, and the sensitivity depended on the electron energy. In addition, the degradation of a substrate-type CdTe solar cell dosimeter by electron beam irradiation was investigated. No significant degradation in short-circuit current was observed at the electron irradiation of 3 × 10^16 /cm^2 at 200 keV and 1 × 10^16 /cm^2 at 400 keV. This result suggests that the substratetype CdTe solar cell dosimeter is sufficiently resistant to electron irradiation.
書誌情報 Japanese Journal of Applied Physics

巻 62, p. SK1004-1-SK1004-5, 発行日 2023-03
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 1347-4065
DOI
識別子タイプ DOI
関連識別子 10.35848/1347-4065/acbd92
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:23:17.613677