ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

SARS-CoV-2 Omicron detection by antigen tests using saliva

https://repo.qst.go.jp/records/2000527
https://repo.qst.go.jp/records/2000527
d078080f-539f-4893-b691-f93e83038c3f
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-07-04
タイトル
タイトル SARS-CoV-2 Omicron detection by antigen tests using saliva
言語 ja
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kaoru Murakami

× Kaoru Murakami

Kaoru Murakami

Search repository
Sumio Iwasaki

× Sumio Iwasaki

Sumio Iwasaki

Search repository
Satoshi Oguri

× Satoshi Oguri

Satoshi Oguri

Search repository
Kumiko Tanaka

× Kumiko Tanaka

Kumiko Tanaka

Search repository
Rigel Suzuki

× Rigel Suzuki

Rigel Suzuki

Search repository
Kasumi Hayasaka

× Kasumi Hayasaka

Kasumi Hayasaka

Search repository
Shinichi Fujisawa

× Shinichi Fujisawa

Shinichi Fujisawa

Search repository
Chiaki Watanabe

× Chiaki Watanabe

Chiaki Watanabe

Search repository
Satoshi Konno

× Satoshi Konno

Satoshi Konno

Search repository
Isao Yokota

× Isao Yokota

Isao Yokota

Search repository
Takasuke Fukuhara

× Takasuke Fukuhara

Takasuke Fukuhara

Search repository
Masaaki Murakami

× Masaaki Murakami

Masaaki Murakami

Search repository
抄録
内容記述タイプ Abstract
内容記述 The Omicron emerged in November 2021 and became the predominant SARS-CoV-2 variant globally. It spreads more rapidly than ancestral lineages and its rapid detection is critical for the prevention of disease outbreaks. Antigen tests such as immunochromatographic assay (ICA) and chemiluminescent enzyme immunoassay (CLEIA) yield results more quickly than standard polymerase chain reaction (PCR). However, their utility for the detection of the Omicron variant remains unclear. We herein evaluated the performance of ICA and CLEIA in saliva from 51 patients with Omicron and 60 PCR negative individuals. The sensitivity and specificity of CLEIA were 98.0% (95%CI: 89.6-100.0%) and 100.0% (95%CI: 94.0-100.0%), respectively, with fine correlation with cycle threshold (Ct) values. The sensitivity and specificity of ICA were 58.8% (95%CI: 44.2-72.4%) and 100.0% (95%CI: 94.0-100.0%), respectively. The sensitivity of ICA was 100.0% (95%CI: 80.5-100.0%) when PCR Ct was less than 25. The Omicron can be efficiently detected in saliva by CLEIA. ICA also detects high viral load Omicron using saliva.
書誌情報 Journal of Clinical Virology Plus

巻 2, 号 4, p. 100109, 発行日 2022-11
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 2667-0380
DOI
識別子タイプ DOI
関連識別子 10.1016/j.jcvp.2022.100109
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:22:39.427290
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3