ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Biokinetic model analysis with DTPA administration for a case of accidental inhalation of actinides in Japan

https://repo.qst.go.jp/records/2000403
https://repo.qst.go.jp/records/2000403
795cb542-9306-43c1-872c-b38e0f5c2d0a
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-02-16
タイトル
タイトル Biokinetic model analysis with DTPA administration for a case of accidental inhalation of actinides in Japan
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Tani Kotaro

× Tani Kotaro

Tani Kotaro

Search repository
Ishigure Nobuhito

× Ishigure Nobuhito

Ishigure Nobuhito

Search repository
Kim Eunjoo

× Kim Eunjoo

Kim Eunjoo

Search repository
Tominaga Takako

× Tominaga Takako

Tominaga Takako

Search repository
Tatsuzaki Hideo

× Tatsuzaki Hideo

Tatsuzaki Hideo

Search repository
Akashi Makoto

× Akashi Makoto

Akashi Makoto

Search repository
Kurihara Osamu

× Kurihara Osamu

Kurihara Osamu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Accidental inhalation intake of plutonium isotopes and 241Am occurred at a Pu research facility in Japan in 2017, and five workers involved in this accident were treated by the administration of Ca/Zn-diethylenetriaminepentaaceticacid (DTPA). For the worker who was most internally exposed, the therapy was continued over one year after the accident. Urinary samples collected before and after each administration were subject to bioassay to evaluate the efficacy of the dose reduction. This study performed numerical analyses using a biokinetic model dealing with 241Am-DTPA with reference to the European Coordinated Network on Radiation Dosimetry (CONRAD) approach, which assumes that the complex of actinides and Ca/Zn-DTPA is generated in the designated compartments in the biokinetic model. The results of the model prediction well captured the trend of the observed urinary excretion in the long-term bioassay and would be useful to evaluate the efficacy of the Ca/Zn-DTPA administration for the worker involved in the accident.
書誌情報 Radiation Protection Dosimetry

巻 199, 号 15-16, p. 2025-2029, 発行日 2023-10
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 1742-3406
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncac224
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:18:37.197187
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3