  1. 原著論文

External dose measurements to investigate the body-size dependence of personal dosemeter responses in areas affected by the fukushima daiichi nuclear accident

https://repo.qst.go.jp/records/2000373
https://repo.qst.go.jp/records/2000373
e78a755c-b175-4868-b8c7-4fc594cee4bb
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-01-25
タイトル
タイトル External dose measurements to investigate the body-size dependence of personal dosemeter responses in areas affected by the fukushima daiichi nuclear accident
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yajima Kazuaki

× Yajima Kazuaki

Yajima Kazuaki

Search repository
Kim Eunjoo

× Kim Eunjoo

Kim Eunjoo

Search repository
Tani Kotaro

× Tani Kotaro

Tani Kotaro

Search repository
Arae Hideki

× Arae Hideki

Arae Hideki

Search repository
Iwaoka Kazuki

× Iwaoka Kazuki

Iwaoka Kazuki

Search repository
Hosoda Masahiro

× Hosoda Masahiro

Hosoda Masahiro

Search repository
Tokonami Shinji

× Tokonami Shinji

Tokonami Shinji

Search repository
Kurihara Osamu

× Kurihara Osamu

Kurihara Osamu

Search repository
Aono Tatsuo

× Aono Tatsuo

Aono Tatsuo

Search repository
抄録
内容記述タイプ Abstract
内容記述 To formulate necessary protective measures after a large-scale nuclear accident, it is crucial to understand the levels of radiation to which persons living in radionuclide-contaminated areas are exposed. Individual monitoring using personal dosemeters (PDs) plays a role in this, although PDs were not originally intended to be used by members of the public. The present study investigated PD responses in areas highly affected by the Fukushima Daiichi nuclear accident, as well as the dependence of those measurements on body size. Three types of commercially available electronic PDs, including D-shuttle, which has often been used in Fukushima, were placed on the front surfaces of three age-specific anthropometric phantoms imitating a 5-y-old, a 10-y-old and an adult male, and these phantoms were then exposed to radiation in an open field in the affected area. In the case of D-shuttle, the ratios of PD readings to the ambient dose rate for the 5-y-old phantom and the adult male phantom were 0.79 and 0.72, respectively. The ratios were somewhat higher for the other PDs; any PDs showed higher readings than the effective doses estimated by simulations based on the assumed ground deposition of 134Cs and/or 137Cs over the affected areas.
書誌情報 Radiation Protection Dosimetry

巻 199, 号 15-16, p. 2000-2004, 発行日 2023-01
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 1742-3406
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncac274
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:17:38.725688
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3