Advantages of using larger-diameter pinhole collimator for prompt X-ray imaging during irradiation with carbon ions

https://repo.qst.go.jp/records/2000194
https://repo.qst.go.jp/records/2000194
a10c9f82-e06a-4f22-a4ba-ec9dc46509aa
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2023-07-03
タイトル
タイトル Advantages of using larger-diameter pinhole collimator for prompt X-ray imaging during irradiation with carbon ions
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Seiichi Yamamoto (Nagoya Univ.)

× Seiichi Yamamoto (Nagoya Univ.)

Seiichi Yamamoto (Nagoya Univ.)

Search repository
Yabe Takuya

× Yabe Takuya

Yabe Takuya

Search repository
Takashi Akagi (Hyogo Ion Beam Medical Center)

× Takashi Akagi (Hyogo Ion Beam Medical Center)

Takashi Akagi (Hyogo Ion Beam Medical Center)

Search repository
Yamaguchi Mitsutaka

× Yamaguchi Mitsutaka

Yamaguchi Mitsutaka

Search repository
Kawachi Naoki

× Kawachi Naoki

Kawachi Naoki

Search repository
Kei Kamada (Tohoku Univ.)

× Kei Kamada (Tohoku Univ.)

Kei Kamada (Tohoku Univ.)

Search repository
Akira Yoshikawa (Tohoku Univ.)

× Akira Yoshikawa (Tohoku Univ.)

Akira Yoshikawa (Tohoku Univ.)

Search repository
Jun Kataoka (Waseda Univ.)

× Jun Kataoka (Waseda Univ.)

Jun Kataoka (Waseda Univ.)

Search repository
抄録
内容記述タイプ Abstract
内容記述 Prompt secondary electron bremsstrahlung X-ray (prompt X-ray) imaging using a low-energy X-ray camera is a promising method for observing a beam shape from outside the subject. However, the images measured within short times suffer from statistical noise. Consequently, we performed prompt X-ray imaging with higher sensitivity using a larger-diameter pinhole collimator and compared the results with those of a conventional collimator. Prompt X-ray imaging was conducted during irradiation with pencil beams of 241.5-MeV/n carbon ions to a water phantom. A newly developed X-ray camera with a 4-mm diameter as well as conventional 1.5-mm-diameter pinhole collimators was used for the imaging in list mode, and we compared the prompt X-ray images, energy spectra, and time count rate curves between 1.5-mm-diameter and 4-mm-diameter pinhole collimators. The prompt X-ray images taken with the 4-mm-diameter pinhole collimators had ?7 times higher sensitivity with 70 % lower offset fractions originating from the prompt gamma photons. Furthermore, the ranges were more precisely estimated with the 4-mm collimator than with the 1.5-mm collimator. The energy spectra showed less contamination by tungsten-characteristic X-rays for the 4-mm pinhole collimator. Even for images measured with 0.1-s intervals, the beam shapes and time count rate curves could be obtained with less statistical noise using the 4-mm-diameter pinhole collimators. The use of the 4-mm-diameter pinhole collimator attached to the X-ray camera had advantages for prompt X-ray imaging with high sensitivity and low background, enabling us to image the beams even with short-time measurements.
書誌情報 Journal of Instrumentation (JINST)

巻 17, p. P09006, 発行日 2022-09
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 1748-0221
DOI
識別子タイプ DOI
関連識別子 10.1088/1748-0221/17/09/P09006
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 01:23:33.001925