ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Axial scalable add-on PET/MRI prototype based on four-layer DOI detectors integrated with a RF coil

https://repo.qst.go.jp/records/2000188
https://repo.qst.go.jp/records/2000188
f4a73011-2bed-4f17-8610-c1bb5ae18c03
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2023-07-03
タイトル
タイトル Axial scalable add-on PET/MRI prototype based on four-layer DOI detectors integrated with a RF coil
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Nishikido Fumihiko

× Nishikido Fumihiko

Nishikido Fumihiko

Search repository
Obata Takayuki

× Obata Takayuki

Obata Takayuki

Search repository
Suga Mikio

× Suga Mikio

Suga Mikio

Search repository
Iwao Yuma

× Iwao Yuma

Iwao Yuma

Search repository
Tashima Hideaki

× Tashima Hideaki

Tashima Hideaki

Search repository
Yoshida Eiji

× Yoshida Eiji

Yoshida Eiji

Search repository
Akram Hossain

× Akram Hossain

Akram Hossain

Search repository
Yamaya Taiga

× Yamaya Taiga

Yamaya Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 We developed an add-on PET which was a PET insert based on 4-layered depth-of-interaction (DOI) detectors integrated with a birdcage RF-coil. The PET detectors were placed close to subjects to achieve high sensitivity. The DOI capability suppress degradation of spatial resolution at the edge of the field of view (FOV). Previously, we developed an first prototype which had a short axial FOV. In order to extend the axial FOV, we developed new scalable add-on PET prototype. The constructed RF-coil of the new prototype was combined with 24 DOI-PET detector units Each detector unit with two PET detectors was shielded with a carbon fiber shielding box. Each PET detector consisted of a 14 × 14 × 4-layer array of lutetium fine silicate crystals (1.9 mm × 1.9 mm × 4.0 mm), an 8 × 8 multi-pixel photon counter (MPPC, S12641PA-050) array and a readout circuit board with an ASIC. The RF coil was tuned for a 3T clinical MRI (MAGNETOM Verio, Siemens). We evaluated performance the scalable add-on PET prototype in simultaneous PET/MRI measurements. We obtained spatial resolutions of 2.0 mm at the center of the FOV and better than 3.3 mm in the whole FOV. The energy resolution of 12.4 % was obtained at 511 keV. In addition, we observed no degradation of PET performance caused by the MRI measurement. The signal-to-noise ratio (SNR) of the MRI image was 186.2 in simultaneous measurements with the PET. The maximum B0 and maximum difference of the secondary magnetic field due to the eddy current effect were smaller than 0.2 ppm and T, respectively. It meant that the influence of the PET detectors on the static magnetic field and secondary magnetic field did not cause problems.
書誌情報 Nuclear Instruments and Methods in Physics Research Section A

巻 1040, p. 167239, 発行日 2022-07
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2022.167239
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 01:23:21.629081
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3