        <jpcoar:jpcoar xmlns:datacite="https://schema.datacite.org/meta/kernel-4/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcndl="http://ndl.go.jp/dcndl/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:jpcoar="https://github.com/JPCOAR/schema/blob/master/1.0/" xmlns:oaire="http://namespace.openaire.eu/schema/oaire/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:rioxxterms="http://www.rioxx.net/schema/v2.0/rioxxterms/" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns="https://github.com/JPCOAR/schema/blob/master/1.0/" xsi:schemaLocation="https://github.com/JPCOAR/schema/blob/master/1.0/jpcoar_scm.xsd">
          <dc:title>2色x線CTを用いた物質同定への基礎実験</dc:title>
          <jpcoar:creator>
            <jpcoar:creatorName>大野, 由美子</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>取越, 正己</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>山田, 聰</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>その他</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">大野 由美子</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">取越 正己</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="en">山田 聰</jpcoar:creatorName>
          </jpcoar:creator>
          <dcterms:accessRights rdf:resource="http://purl.org/coar/access_right/c_14cb">metadata only access</dcterms:accessRights>
          <datacite:description descriptionType="Abstract">We have developed dual energy x-ray CT using monochromatic X-ray beams from synchrotron radiation. From the dual-energy X-ray CT , we can obtain distributions of an electron density and an effective atomic measured pe and Z images of some solution samples and medical materials by DECT. We will report of experimental results contributing to the treatment planning of radiation therapy and discuss an application possibility to material identification.</datacite:description>
          <datacite:date dateType="Issued">2007-06</datacite:date>
          <dc:language>jpn</dc:language>
          <dc:type rdf:resource="http://purl.org/coar/resource_type/c_5794">conference paper</dc:type>
          <jpcoar:identifier identifierType="URI">https://repo.qst.go.jp/records/53895</jpcoar:identifier>
          <jpcoar:sourceIdentifier identifierType="ISSN">1344-4514</jpcoar:sourceIdentifier>
          <jpcoar:sourceTitle>Proceedings of the Symposium on Accelerator and Related Technology for Application</jpcoar:sourceTitle>