量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
We report the dose measurement technique for emitted particles from Cu-64 source using a combination of Fluorescent Nuclear Track Detector (FNTD), which is Al2O3 single crystal doped with C and Mg, and Monte Carlo simulations in the PHITS code and Geant4 toolkit. The relatively high fluorescence intensity induced by Auger electrons is observed at the FNTD surface. Then, the fluorescence intensity monotonically reduces as the depth from the surface increases. The results obtained using the PHITS Monte Carlo simulation code is very similar to that of Geant4. Also, the simulations are in good agreement with experimental results. These findings prove that the signal induced by Auger electrons is successfully measured using FNTD. Additionally, the high signal at the FNTD surface implies that Auger electrons can work effectively to kill cancer cells proximal to a Cu-64 source while minimizing damage effects on normal cells distal to the source. At 15 μm depth in the crystal, which is the mean tissue cell radius, the relative dose of beta particles is about 24% of that at the FNTD surface. Therefore, the contribution of free radicals created by beta particles should be accounted for to clarify the impact of Cu-64 on tissues.