量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
The cooling-stacking injection at the HIMAC synchrotron was used to increase the intensity of Ar18+ ion beam. The beam stacking was realized in a horizontal free
phase-space, which was created by the HIMAC electron cooler. The stack intensity of (1.5-2.5) / 109 ppp was accumulated at an injection intensity of (0.3-1.0)/109.
The lifetime of stack ions is determined by vacuum pressure. The new injected ions were slowly lost at multiple scattering on residual gas atoms at diffusion heating in the vertical direction caused by the acceptance of 30 pi mmmrad and a reduction of cooling force at large betatron amplitudes. The results of numerical simulations and experimental study of cooling-stacking injection on the HIMAC synchrotron are presented.