WEKO3
アイテム
{"_buckets": {"deposit": "e704d431-4199-463f-b954-8436d7a410fc"}, "_deposit": {"created_by": 1, "id": "81942", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "81942"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00081942", "sets": ["1"]}, "author_link": ["1009956", "1009957", "1009958", "1009960", "1009955", "1009959"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageStart": "6400105", "bibliographicVolumeNumber": "57", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Magnetics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Although the observation of magnetic domains well below the surface of a sample appears to be relatively easy, in reality, magnetic domains inside metallic samples have not been investigated in detail due to a lack of adequate techniques. Non-resonant magnetic X-ray diffraction (NRMXRD) is a candidate for such 3-D magnetic microscopy. A relatively small focus size of less than 100 nm and a relatively long attenuation length of more than 100 μm can be obtained by using high-energy synchrotron X-rays. However, NRMXRD has a disadvantage in that the magnetic contrast is low. It is known that the magnetic contrast in NRMXRD increases with increasing the total polarization of the incident X-rays. In this feasibility study, we carried out NRMXRD experiments on a metallic iron sample to examine whether the magnetic contrast can be sufficiently enhanced even for high-energy X-rays.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/TMAG.2020.3046006", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://ieeexplore.ieee.org/document/9300151", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9464", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Toshiya, Inami"}], "nameIdentifiers": [{"nameIdentifier": "1009955", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahisa, Shobu"}], "nameIdentifiers": [{"nameIdentifier": "1009956", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kenji, Ishii"}], "nameIdentifiers": [{"nameIdentifier": "1009957", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Toshiya, Inami", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1009958", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahisa, Shobu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1009959", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kenji, Ishii", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1009960", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Feasibility Study of Magnetic-Domain Observation by Means of Non-Resonant Magnetic X-Ray Diffraction", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Feasibility Study of Magnetic-Domain Observation by Means of Non-Resonant Magnetic X-Ray Diffraction"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/81942", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-02-22"}, "publish_date": "2021-02-22", "publish_status": "0", "recid": "81942", "relation": {}, "relation_version_is_last": true, "title": ["Feasibility Study of Magnetic-Domain Observation by Means of Non-Resonant Magnetic X-Ray Diffraction"], "weko_shared_id": -1}
Feasibility Study of Magnetic-Domain Observation by Means of Non-Resonant Magnetic X-Ray Diffraction
https://repo.qst.go.jp/records/81942
https://repo.qst.go.jp/records/8194248936618-f2af-4510-a7a2-dabf561cfd5b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-02-22 | |||||
タイトル | ||||||
タイトル | Feasibility Study of Magnetic-Domain Observation by Means of Non-Resonant Magnetic X-Ray Diffraction | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Toshiya, Inami
× Toshiya, Inami× Takahisa, Shobu× Kenji, Ishii× Toshiya, Inami× Takahisa, Shobu× Kenji, Ishii |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Although the observation of magnetic domains well below the surface of a sample appears to be relatively easy, in reality, magnetic domains inside metallic samples have not been investigated in detail due to a lack of adequate techniques. Non-resonant magnetic X-ray diffraction (NRMXRD) is a candidate for such 3-D magnetic microscopy. A relatively small focus size of less than 100 nm and a relatively long attenuation length of more than 100 μm can be obtained by using high-energy synchrotron X-rays. However, NRMXRD has a disadvantage in that the magnetic contrast is low. It is known that the magnetic contrast in NRMXRD increases with increasing the total polarization of the incident X-rays. In this feasibility study, we carried out NRMXRD experiments on a metallic iron sample to examine whether the magnetic contrast can be sufficiently enhanced even for high-energy X-rays. | |||||
書誌情報 |
IEEE Transactions on Magnetics 巻 57, 号 3, p. 6400105, 発行日 2021-03 |
|||||
出版者 | ||||||
出版者 | IEEE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9464 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TMAG.2020.3046006 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://ieeexplore.ieee.org/document/9300151 |