WEKO3
アイテム
{"_buckets": {"deposit": "136e53c8-bf39-4c70-a303-791990e16116"}, "_deposit": {"created_by": 1, "id": "81852", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "81852"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00081852", "sets": ["1"]}, "author_link": ["1010031", "1010032", "1010030", "1010029"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "875", "bibliographicPageStart": "869", "bibliographicVolumeNumber": "327", "bibliographic_titles": [{"bibliographic_title": "Journal of Radioanalytical and Nuclear Chemistry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Astatine was separated from a lead target, irradiated with 7Li ion beams, by dry distillation. Dry distillation was conducted in a glass test tube filled with nitrogen gas by heating the test tube with an electric furnace at 650 ℃. The optimized conditions of the dry distillation procedure were studied by monitoring astatine radioactivity with gamma-ray spectrometers. The separation of astatine was accomplished in ~10 min. The cooling of the middle portion of the test tube was instrumental in recovering astatine radioactivity in high yields. The adsorption temperature of astatine on the glass surface was ~20 ℃.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Nature"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s10967-020-07546-2", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://link.springer.com/article/10.1007/s10967-020-07546-2", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0236-5731", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nishinaka, Ichiro"}], "nameIdentifiers": [{"nameIdentifier": "1010029", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hashimoto, Kazuyuki"}], "nameIdentifiers": [{"nameIdentifier": "1010030", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ichiro, Nishinaka", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1010031", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kazuyuki, Hashimoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1010032", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/81852", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-12-11"}, "publish_date": "2020-12-11", "publish_status": "0", "recid": "81852", "relation": {}, "relation_version_is_last": true, "title": ["Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube"], "weko_shared_id": -1}
Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube
https://repo.qst.go.jp/records/81852
https://repo.qst.go.jp/records/81852090dc072-95e6-49ad-ae0e-ed925cb6a79a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-12-11 | |||||
タイトル | ||||||
タイトル | Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nishinaka, Ichiro
× Nishinaka, Ichiro× Hashimoto, Kazuyuki× Ichiro, Nishinaka× Kazuyuki, Hashimoto |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Astatine was separated from a lead target, irradiated with 7Li ion beams, by dry distillation. Dry distillation was conducted in a glass test tube filled with nitrogen gas by heating the test tube with an electric furnace at 650 ℃. The optimized conditions of the dry distillation procedure were studied by monitoring astatine radioactivity with gamma-ray spectrometers. The separation of astatine was accomplished in ~10 min. The cooling of the middle portion of the test tube was instrumental in recovering astatine radioactivity in high yields. The adsorption temperature of astatine on the glass surface was ~20 ℃. | |||||
書誌情報 |
Journal of Radioanalytical and Nuclear Chemistry 巻 327, 号 2, p. 869-875, 発行日 2021-01 |
|||||
出版者 | ||||||
出版者 | Springer Nature | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0236-5731 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s10967-020-07546-2 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://link.springer.com/article/10.1007/s10967-020-07546-2 |