WEKO3
アイテム
{"_buckets": {"deposit": "5a9cb6b8-a1f1-4a24-93b5-c8cfee9a5fe3"}, "_deposit": {"created_by": 1, "id": "80398", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "80398"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00080398", "sets": ["1"]}, "author_link": ["888408", "888407", "888405", "888403", "888404", "888406", "888402", "888409"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "323", "bibliographicPageStart": "320", "bibliographicVolumeNumber": "190", "bibliographic_titles": [{"bibliographic_title": "Radiation Protection Dosimetry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The caesium retention characteristics of a potassium-nickel hexacyanoferrate resin in a polyacrylnitrile (KNiFC–PAN) matrix were tested in fresh water over the range of 2.5–400 mL min −1 . The experimental setup used 2 mL resin and 4-L aliquots of freshwater samples. The results showed nearly 100% retention at speeds below 10 mL min −1 , above 80% up to 100 mL min −1 , and approached 50% at 400 mL min −1 . Using 100 mL min −1 flow rate and KNiFC–PAN resin in a well-type HPGe detector, the minimum detectable concentration was reduced to 3 mBq kg −1 for 4-L aliquots of water samples from the previous 15 mBq kg −1 achieved by Powdex ion-exchange resin and a planar type HPGe detector.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Oxford University Press."}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1093/rpd/ncaa109", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncaa109/5893982", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0144-8420", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Miklós, Hegedűs"}], "nameIdentifiers": [{"nameIdentifier": "888402", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tazoe , Hirofumi"}], "nameIdentifiers": [{"nameIdentifier": "888403", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yang, Guosheng"}], "nameIdentifiers": [{"nameIdentifier": "888404", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tamakuma , Yuki"}], "nameIdentifiers": [{"nameIdentifier": "888405", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hosoda , Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "888406", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akata , Naofumi"}], "nameIdentifiers": [{"nameIdentifier": "888407", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tokonami, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "888408", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yang, Guosheng", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "888409", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Caesium retention characteristics of knifc–pan resin from river water", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Caesium retention characteristics of knifc–pan resin from river water"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/80398", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-09-01"}, "publish_date": "2020-09-01", "publish_status": "0", "recid": "80398", "relation": {}, "relation_version_is_last": true, "title": ["Caesium retention characteristics of knifc–pan resin from river water"], "weko_shared_id": -1}
Caesium retention characteristics of knifc–pan resin from river water
https://repo.qst.go.jp/records/80398
https://repo.qst.go.jp/records/80398aac5f9d3-7dc4-4192-84b6-d29f0891792a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-09-01 | |||||
タイトル | ||||||
タイトル | Caesium retention characteristics of knifc–pan resin from river water | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Miklós, Hegedűs
× Miklós, Hegedűs× Tazoe , Hirofumi× Yang, Guosheng× Tamakuma , Yuki× Hosoda , Masahiro× Akata , Naofumi× Tokonami, Shinji× Yang, Guosheng |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The caesium retention characteristics of a potassium-nickel hexacyanoferrate resin in a polyacrylnitrile (KNiFC–PAN) matrix were tested in fresh water over the range of 2.5–400 mL min −1 . The experimental setup used 2 mL resin and 4-L aliquots of freshwater samples. The results showed nearly 100% retention at speeds below 10 mL min −1 , above 80% up to 100 mL min −1 , and approached 50% at 400 mL min −1 . Using 100 mL min −1 flow rate and KNiFC–PAN resin in a well-type HPGe detector, the minimum detectable concentration was reduced to 3 mBq kg −1 for 4-L aliquots of water samples from the previous 15 mBq kg −1 achieved by Powdex ion-exchange resin and a planar type HPGe detector. | |||||
書誌情報 |
Radiation Protection Dosimetry 巻 190, 号 3, p. 320-323, 発行日 2020-09 |
|||||
出版者 | ||||||
出版者 | Oxford University Press. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0144-8420 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/rpd/ncaa109 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncaa109/5893982 |