WEKO3
アイテム
{"_buckets": {"deposit": "741967d8-5ad0-4b09-ac57-8a522393f297"}, "_deposit": {"created_by": 1, "id": "80233", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "80233"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00080233", "sets": ["1"]}, "author_link": ["880751", "880752", "880753", "880749", "880750", "880754"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageStart": "11611", "bibliographicVolumeNumber": "10", "bibliographic_titles": [{"bibliographic_title": "Scientific reports"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with intricate dependence on magnitude and phase, complicating high throughput detection of each parameter. In this study, a simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated by a sequential measurement protocol. Wide-field imaging experiment was performed for an oscillating magnetic field with approximately [Formula: see text]-squared observation area. Single pixel phase precision was [Formula: see text] for [Formula: see text] AC magnetic signal. Our method enables potential applications including inductive inspection and impedance imaging.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Nature Publishing Group"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "32665566", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1038/s41598-020-68404-5", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.nature.com/articles/s41598-020-68404-5", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2045-2322", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mizuno, Kosuke"}], "nameIdentifiers": [{"nameIdentifier": "880749", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishiwata, Hitoshi"}], "nameIdentifiers": [{"nameIdentifier": "880750", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masuyama, Yuta"}], "nameIdentifiers": [{"nameIdentifier": "880751", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwasaki, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "880752", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatano, Mutsuko"}], "nameIdentifiers": [{"nameIdentifier": "880753", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masuyama, Yuta", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "880754", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/80233", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-07-28"}, "publish_date": "2020-07-28", "publish_status": "0", "recid": "80233", "relation": {}, "relation_version_is_last": true, "title": ["Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry."], "weko_shared_id": -1}
Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry.
https://repo.qst.go.jp/records/80233
https://repo.qst.go.jp/records/802336cb374ed-796d-45e4-b269-cc6c137d9c55
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-07-28 | |||||
タイトル | ||||||
タイトル | Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mizuno, Kosuke
× Mizuno, Kosuke× Ishiwata, Hitoshi× Masuyama, Yuta× Iwasaki, Takayuki× Hatano, Mutsuko× Masuyama, Yuta |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with intricate dependence on magnitude and phase, complicating high throughput detection of each parameter. In this study, a simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated by a sequential measurement protocol. Wide-field imaging experiment was performed for an oscillating magnetic field with approximately [Formula: see text]-squared observation area. Single pixel phase precision was [Formula: see text] for [Formula: see text] AC magnetic signal. Our method enables potential applications including inductive inspection and impedance imaging. | |||||
書誌情報 |
Scientific reports 巻 10, 号 1, p. 11611, 発行日 2020-07 |
|||||
出版者 | ||||||
出版者 | Nature Publishing Group | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2045-2322 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 32665566 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1038/s41598-020-68404-5 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.nature.com/articles/s41598-020-68404-5 |