WEKO3
アイテム
{"_buckets": {"deposit": "a6b555d0-6b51-4ae6-8ade-b3370f91cc69"}, "_deposit": {"created_by": 1, "id": "78565", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78565"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078565", "sets": ["1"]}, "author_link": ["1070427", "1070429", "1070422", "1070426", "1070423", "1070428", "1070424", "1070425"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "106252", "bibliographicVolumeNumber": "132", "bibliographic_titles": [{"bibliographic_title": "Radiation Measurements"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Silver-activated phosphate glass (Ag+-glass), which is commonly employed as a radiophotoluminscence (RPL) dosimeter, was applied as a fluorescent nuclear track detector (FNTD). The heavy ions from C to Fe ions were detected as fluorescent nuclear tracks under a confocal microscope. The detection linear energy transfer (LET) threshold was estimated to be 5 keV/μm in water. The fading effect was observed in which the fluorescent intensity decreases with repeated laser scans. The Ag+-glass has good potential applicability as the FNTD for the high LET range (5– 200 keV/μm) in radioimmunotherapy and space radiation dosimetry uses.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.radmeas.2020.106252", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1016/j.radmeas.2020.106252", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1350-4487", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kodaira, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "1070422", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kusumoto, Tamon"}], "nameIdentifiers": [{"nameIdentifier": "1070423", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, Hisashi"}], "nameIdentifiers": [{"nameIdentifier": "1070424", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yanagida, Yuka"}], "nameIdentifiers": [{"nameIdentifier": "1070425", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koguchi, Yasuhiro"}], "nameIdentifiers": [{"nameIdentifier": "1070426", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satoshi, Kodaira", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1070427", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tamon, Kusumoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1070428", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hisashi, Kitamura", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1070429", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Characteristics of fluorescent nuclear track detection with Ag+-activated phosphate glass", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Characteristics of fluorescent nuclear track detection with Ag+-activated phosphate glass"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/78565", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-01-29"}, "publish_date": "2020-01-29", "publish_status": "0", "recid": "78565", "relation": {}, "relation_version_is_last": true, "title": ["Characteristics of fluorescent nuclear track detection with Ag+-activated phosphate glass"], "weko_shared_id": -1}
Characteristics of fluorescent nuclear track detection with Ag+-activated phosphate glass
https://repo.qst.go.jp/records/78565
https://repo.qst.go.jp/records/78565183755d5-ab86-4b77-8626-2bb90182fbf9
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-01-29 | |||||
タイトル | ||||||
タイトル | Characteristics of fluorescent nuclear track detection with Ag+-activated phosphate glass | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kodaira, Satoshi
× Kodaira, Satoshi× Kusumoto, Tamon× Kitamura, Hisashi× Yanagida, Yuka× Koguchi, Yasuhiro× Satoshi, Kodaira× Tamon, Kusumoto× Hisashi, Kitamura |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Silver-activated phosphate glass (Ag+-glass), which is commonly employed as a radiophotoluminscence (RPL) dosimeter, was applied as a fluorescent nuclear track detector (FNTD). The heavy ions from C to Fe ions were detected as fluorescent nuclear tracks under a confocal microscope. The detection linear energy transfer (LET) threshold was estimated to be 5 keV/μm in water. The fading effect was observed in which the fluorescent intensity decreases with repeated laser scans. The Ag+-glass has good potential applicability as the FNTD for the high LET range (5– 200 keV/μm) in radioimmunotherapy and space radiation dosimetry uses. | |||||
書誌情報 |
Radiation Measurements 巻 132, p. 106252, 発行日 2020-03 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1350-4487 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.radmeas.2020.106252 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.radmeas.2020.106252 |