Vrain: a brain-dedicated hemispherical PET system evolved from a lab bench prototype

https://repo.qst.go.jp/records/86255
https://repo.qst.go.jp/records/86255
3614beae-3ce8-4816-b143-1dde726a3c68
Item type 会議発表用資料 / Presentation(1)
公開日 2022-06-06
タイトル
タイトル Vrain: a brain-dedicated hemispherical PET system evolved from a lab bench prototype
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Go, Akamatsu

× Go, Akamatsu

WEKO 1049478

Go, Akamatsu

Search repository
Miwako, Takahashi

× Miwako, Takahashi

WEKO 1049479

Miwako, Takahashi

Search repository
Yuma, Iwao

× Yuma, Iwao

WEKO 1049480

Yuma, Iwao

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 1049481

Hideaki, Tashima

Search repository
Eiji, Yoshida

× Eiji, Yoshida

WEKO 1049482

Eiji, Yoshida

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1049483

Taiga, Yamaya

Search repository
Go, Akamatsu

× Go, Akamatsu

WEKO 1049484

en Go, Akamatsu

Search repository
Miwako, Takahashi

× Miwako, Takahashi

WEKO 1049485

en Miwako, Takahashi

Search repository
Yuma, Iwao

× Yuma, Iwao

WEKO 1049486

en Yuma, Iwao

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 1049487

en Hideaki, Tashima

Search repository
Eiji, Yoshida

× Eiji, Yoshida

WEKO 1049488

en Eiji, Yoshida

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1049489

en Taiga, Yamaya

Search repository
抄録
内容記述タイプ Abstract
内容記述 [Objectives] A PET system can be more efficient in terms of size and cost when it is designed as an organ-dedicated or application-specific system. Considering the potential need for brain PET, we proposed the concept of a hemispherical detector arrangement, which enables higher sensitivity with fewer number of detectors than a conventional cylindrical geometry has. A laboratory benchtop prototype has been evolved into a complete brain PET system, which has been commercialized in Japan under the product name of VrainTM. In this work, we characterize the system and carry out its first human imaging tests.

[Methods] The VrainTM has 54 detectors. A hemispherical part is formed by 45 detectors and the other 9 detectors are located at the backside of the neck. Each detector is a one-to-one combination of lutetium-based scintillators (crystal element size: 4.1×4.1×10 mm3) and silicon photomultipliers (SiPMs) (active area size: 4×4 mm2). The inner diameter of the bottom detector ring is 279 mm. The crystal thickness is optimized by simulation to reduce the parallax error and to improve the TOF performance. The energy window is also optimized to 450–590 keV to get better image quality. We evaluated the physical performance of the VrainTM according to the NEMA NU 2-2018 standards. Some measurements were added and others were modified to suit the hemispherical detector arrangement. Finally, we carried out the first healthy volunteer imaging. 18F-FDG of 3.7 MBq/kg was intravenously injected to a male subject (42 years old). The PET measurement duration was 10 min starting at 45 min after injection. PET images were reconstructed using the OSEM with 4 iterations and 8 subsets. A Gaussian filter of 4 mm FWHM was applied to PET images. CT images, which were obtained by another PET/CT scanner, were used for attenuation and scatter corrections.

[Results] The 2.2 mm rods of a small rod phantom were resolved. The TOF resolution at the peak noise-equivalent count ratio (NECR) (9.8 kBq/mL) was 256 ps and the TOF gain in sensitivity was calculated as 5.2 (20 cm diameter / 3.8 cm localization accuracy). The effective sensitivity was 21.8 kcps/MBq and the effective peak NECR was 129 kcps at 9.8 kBq/mL. The sensitivity was higher at the upper position in the axial direction. For the brain-sized image quality phantom evaluation, the percent contrast of the 10 mm sphere was 48% with the percent background variability of 8.6%. For the human FDG PET imaging, the whole brain was successfully imaged without any artifacts. Gray and white matters were clearly visualized with a high contrast.

[Conclusion] The helmet-type brain PET system VrainTM showed 2.2 mm spatial resolution, 256 ps TOF resolution, and excellent image quality. The brain FDG PET images of the healthy volunteer were high contrast and low noise. Further studies are warranted to assess the potential clinical impact of PET imaging with the VrainTM.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 SNMMI 2022 Annual Meeting
発表年月日
日付 2022-06-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:50:23.110822
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3